background image

- 3 - 

NOVATEK-ELECTRO 

                                                                                                                            

REV-120

 

This  Operation  Manual  is  intended  to  familiarize  you  with  arrangement,  the  requirements  for  safety, 

operation  and  maintenance  procedures  of  the  time  delay  relay  REV

–120

 

(hereinafter  referred  to  as  the 

"product", "REV

–120"). 

 

The product meets the requirements of the following: 

 Low-voltage switchgear; Part 1; General rules (IEC 60947-1); 

 Low-voltage  circuit  breaker  and  controller;  Part  6-2;  multifunctional  equipment;  Control  and  safety 

switching equipment 

(ІEC 60947-6-2); 

 Electromagnetic  compatibility;  Industrial,  scientific  and  medical  RF  equipment;  electromagnetic 

interference characteristics; standards and measuring procedure (CISPR 11); 

 Electromagnetic  compatibility;  Part  4-2;  Testing  and  measurement  techniques;  Electrostatic  discharge 

immunity test (IEC 61000-4-2). 

 

Harmful substances in amounts exceeding maximum permissible concentrations are not available. 

 

Terms and abbreviations: 

 It periodically flashes 

– the indicator short-time enabling. 

 It periodically is off 

– the indicator short-time disabling. 

 

 
1. APPLICATION 
 
1.1. Product application 

The time delay relay REV-120 is the microprocessor-based device intended for on/off switching the load in 

user-defined time intervals. 

REV-120 can be operated by ten operation modes: 

 on-delay; 

 time delay when energizing; 

 periodic with on-delay; 

 periodic with time delay when energizing; 

 off-delay (when control contact opening); 

 pulse I (when control contact closing); 

 pulse II (when control contact opening); 

 on/off delay

 

(according to control contact); 

 pitch of the load relay (during each control contact closing); 

 pulse generator of 0.5 s. 

 

1.2. Software revision history 

        19.05.2016    v2    

Primary version of the program

 

 

 

1.3. Controls, overall and mounting dimensions of REV

–120 

Controls, overall and mounting dimensions are shown in Fig.1.

 

 

 
 

1

 

– input contacts ~230/240 V 

L

N

– input control contact 

S

3

 

– regulator for setting the time interval 

∆T

4

 

– regulator for setting the time 

Т

5

 

– regulator for setting the operation mode 

W

6

7

 

– output contacts of load relay: 

NO1 / NO2

 

– normally open contact (further 

NO

); 

NC1 / NC2

 

– normally closed contact 

(further 

NC

); 

С1 / С2

 

– switching contact (further 

С

); 

8

 

– LED indicator of load relay ON; 

9

 

– LED indicator of power ON. 

 
 

 

Fig.1 

– 

Controls, overall and mounting dimensions of REV

–120 

Содержание REV-120

Страница 1: ...system of development and production complies with the requirements of ISO 9001 2015 Dear Customer Company thanks you for purchasing our products You will be able to use properly the product after ca...

Страница 2: ...ATE THE PRODUCT WITH MECHANICAL DAMAGES OF THE CASE IT IS NOT ALLOWED WATER PENETRATION ON TERMINALS AND INTERNAL ELEMENTS OF THE PRODUCT During operation and maintenance the regulatory document requi...

Страница 3: ...ng 1 APPLICATION 1 1 Product application The time delay relay REV 120 is the microprocessor based device intended for on off switching the load in user defined time intervals REV 120 can be operated b...

Страница 4: ...5 Accuracy of time setting accuracy of scale no less than 2 5 Number of operation modes 10 Adjustment range of time is divided into 10 subranges 0 1 1 s 1 10 s 6 s 1 min 1 10 min 6 min 1 h 1 10 h 0 1...

Страница 5: ...lectrical connections you should use flexible stranded wires with insulation for voltage of no less than 450 V the ends of which it is necessary to be striped of insulation for 5 0 5 mm and tightened...

Страница 6: ...y is off At the end of the delay time the load relay contacts are opened the indicator ON of the load relay is off and the product goes into standby mode until power off Periodic with on delay After e...

Страница 7: ...1 it 8 is off When control contact S is closed the load relay contacts are closed the indicator ON of the load relay is on and the set delay time t regulator occurs During the delay time the indicator...

Страница 8: ...open and the indicator ON of the load relay Fig 1 it 8 is off When control contact S is closed the load relay contacts and the indicator ON of the load relay change its state to the opposite and the p...

Страница 9: ...ponds to the open condition of the contacts NO1 C1 NO2 C2 and the closed condition of the contacts NC1 C1 NC2 C2 Periodic flashing of LED indicator of the load relay indicates the time delay after whi...

Страница 10: ...transfer it to the warranty post warranty service in the field of the claims data list the detailed reason for return 6 TRANSPORTATION AND STORAGE The product in the original package is permitted to...

Отзывы: