background image

- 10 - 

REV-120

                                                                                                                            

NOVATEK-ELECTRO

 

3) If necessary, wipe with cloth the front panel and the product housing. 

 

Do not use abrasives and solvents for cleaning. 

 

5. SERVICE LIFE AND MANUFACTURER WARRANTY 
 
5.1.

 The lifetime of the product is 10 years. Upon expiration of the service life, contact the manufacturer. 

 
5.2.

 Shelf life is 3 years. 

 
5.3.

 Warranty period of the product operation is 5 years from the date of sale. 

During  the  warranty  period  of  operation  (in  the  case  of  failure  of  the  product)  the  manufacturer  is 

responsible for free repair of the product. 

 

 
ATTENTION! IF THE PRODUCT HAS BEEN OPERATED IN VIOLATION OF THE REQUIREMENTS OF 

THIS MANUAL, THE MANUFACTURER HAS THE RIGHT TO REFUSE IN WARRANTY SERVICE. 

 

 
5.4.

 Warranty service is performed at the place of purchase or by the manufacturer of the product. 

 
5.5.

 Post-warranty service of the product is performed by the manufacturer at current rates. 

 
5.6.

  Before  sending  for  repair,  the  product  should  be  packed  in  the  original  or  other  packing  excluding 

mechanical damage. 

 
You  are  kindly  requested,  in  case  of  return  of  the  product  and  transfer  it  to  the  warranty  (post-

warranty) servicein the field of the claims data, list the detailed reason for return. 

 

6. TRANSPORTATION AND STORAGE 

The  product  in  the  original  package  is  permitted  to  be  transported  and  stored  at  the  temperature  from 

minus 45 to +60 °C and relative humidity of no more than 80 %. 

 
7. ACCEPTANCE CERTIFICATE 

REV

–120 has been manufactured and accepted in accordance with the requirements of current technical 

documentation and classified as fit for operation. 

 

 
Seal                                                          Head of QCD                           Date of manufacture 
 

                                                                 _____________                       _____________ 

 
8. CLAIMS DATA

 

_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________ 

 

The  Company  is  grateful  to  you  for  the  information  about  the  quality  of  the  product  and  suggestions  for  its 
operation. 

 

For all questions, please contact the manufacturer:

 

NOVATEK ELECTRO INDIA PVT. LTD. 
C-30, Patparganj Industrial Area, F.I.E. 
Delhi 

– 110092, INDIA; 

Tel.: +91 11 42143253 
Tel./fax: +91 11 43010600 

www.novatek-electro.in

 

 

 

Date of sale __________  
 
 

Содержание REV-120

Страница 1: ...system of development and production complies with the requirements of ISO 9001 2015 Dear Customer Company thanks you for purchasing our products You will be able to use properly the product after ca...

Страница 2: ...ATE THE PRODUCT WITH MECHANICAL DAMAGES OF THE CASE IT IS NOT ALLOWED WATER PENETRATION ON TERMINALS AND INTERNAL ELEMENTS OF THE PRODUCT During operation and maintenance the regulatory document requi...

Страница 3: ...ng 1 APPLICATION 1 1 Product application The time delay relay REV 120 is the microprocessor based device intended for on off switching the load in user defined time intervals REV 120 can be operated b...

Страница 4: ...5 Accuracy of time setting accuracy of scale no less than 2 5 Number of operation modes 10 Adjustment range of time is divided into 10 subranges 0 1 1 s 1 10 s 6 s 1 min 1 10 min 6 min 1 h 1 10 h 0 1...

Страница 5: ...lectrical connections you should use flexible stranded wires with insulation for voltage of no less than 450 V the ends of which it is necessary to be striped of insulation for 5 0 5 mm and tightened...

Страница 6: ...y is off At the end of the delay time the load relay contacts are opened the indicator ON of the load relay is off and the product goes into standby mode until power off Periodic with on delay After e...

Страница 7: ...1 it 8 is off When control contact S is closed the load relay contacts are closed the indicator ON of the load relay is on and the set delay time t regulator occurs During the delay time the indicator...

Страница 8: ...open and the indicator ON of the load relay Fig 1 it 8 is off When control contact S is closed the load relay contacts and the indicator ON of the load relay change its state to the opposite and the p...

Страница 9: ...ponds to the open condition of the contacts NO1 C1 NO2 C2 and the closed condition of the contacts NC1 C1 NC2 C2 Periodic flashing of LED indicator of the load relay indicates the time delay after whi...

Страница 10: ...transfer it to the warranty post warranty service in the field of the claims data list the detailed reason for return 6 TRANSPORTATION AND STORAGE The product in the original package is permitted to...