Reinstall new brush into motor housing and replace the retaining clip. Be sure to properly
seat the nub on the bottom of the brush holder into the motor housing groove.
6.
Repeat steps 2 thru 5 for the adjacent brush.
7.
Replace the plastic shield on top of the motor by aligning it on top of the motor and pushing
down until the spring clips on each brush snap into place.
8.
Reinstall metal cover over motor.
11.6- MOTOR REPLACEMENT
Disconnect all power from the loader system. Disconnect the motor wiring from the junction box
located on the lid of the chamber. Remove the three springs that clamp the motor to the lid. The
motor can now be removed. Check the gasket that seals the vacuum motor to the lid and renew if
necessary. Reverse the above steps to install the vacuum motor. Connect power and verify that
the system is operating correctly.