Model and Part Numbers

The part numbers shown in Table 1 should be used to order the necessary Novar
parts.

Table 1.  Novar Part Numbers

PRODUCT

MODEL NO.

PART NO.

Lingo SE Baseplate

Lingo/2-BPL

750110000

Lingo SE Electronics Assembly (no
options)

Options

:

Lingo SE with Integral Touchscreen
Lingo SE with Integral Touchscreen &
Modem
Lingo SE with Modem
Lingo SE with INCOM
Lingo SE with Modem & INCOM
Lingo SE with Touchscreen & INCOM
Lingo SE with Touchscreen, Modem, &
INCOM







750017000

750018000
750018100
750017100
750017010
750017110
750018010
750018110

24-VAC, 40 VA, Class 2 Transformer Kit

24V-XFR

730090000

Analog Light Sensor

ALS-300

708100000

Outdoor Temperature Sensor

OTS/2

735070000

Two-conductor, shielded cable (Belden
8761 equivalent)

WIR-1010

709001000

Ethernet

®

 Direct-Connect Crossover Cable

770077000

Logic One

®

 and Lingo

®

 are registered trademarks of Novar.

INCOM™ is a trademark of Eaton Cutler-Hammer.

Ethernet

®

 is a registered trademark of Xerox Corporation.

The material in this manual is for information purposes only.  The contents and the product it describes 

are subject to change without notice.  Novar makes no representations or warranties with respect to this manual.

In no event shall Novar be liable for technical or editorial omissions or mistakes in this manual, nor shall it be liable

for any damages, direct or incidental, arising out of or related to the use of this manual.  No part of this manual

may be reproduced in any form or by any means without prior written permission from Novar.  

Copyright © 2006 by Novar.  All Rights Reserved.  Printed in the U.S.A.

Novar; 6060 Rockside Woods Blvd., Cleveland, OH  44131

Tel.: 800.348.1235   www.novar.com

8

DOC. #569066200—C  8/17/06

Lingo

®

 SE Baseplate Installation Instructions

Содержание Lingo SE

Страница 1: ...ol to cut energy costs increase comfort and reduce equipment maintenance This document provides instructions for mounting and wiring the Lingo SE baseplate and checking the installation Lingo SE Speci...

Страница 2: ...f the transformer for this module Make sure that the Lingo SE power cannot be switched off accidentally The Lingo SE requires continuous power for proper operation Mounting the Lingo SE Baseplate to t...

Страница 3: ...baseplate 4 Drill holes in the places marked on the wall 5 Install the hollow wall or other appropriate fasteners 6 Turn appropriate screws into the fasteners until approximately one quarter inch rem...

Страница 4: ...round 4 Apply power and check voltage at the 24 VAC terminals Voltage should be approximately 24 to 28 VAC 5 Turn off the power until needed 4 DOC 569066200 C 8 17 06 Lingo SE Baseplate Installation I...

Страница 5: ...r equivalent wiring Step Procedure 1 Connect the white wire from the sensor to the Lingo SE at Terminal 25 at the Outdoor Light Sensor input connections 2 Connect the black wire from the sensor to the...

Страница 6: ...an emergency monitoring system to Terminals 32 and 33 labeled Emergency Status Input System Fault Output Under normal operating conditions a normally open set of contacts will be held closed When an a...

Страница 7: ...inals 19 21 Step Procedure 1 Connect the black wire from the INCOM cable to Terminal 21 INCOM 2 2 Connect the white wire from the INCOM cable to Terminal 20 INCOM 1 3 Connect the shield wire from the...

Страница 8: ...net Direct Connect Crossover Cable 770077000 Logic One and Lingo are registered trademarks of Novar INCOM is a trademark of Eaton Cutler Hammer Ethernet is a registered trademark of Xerox Corporation...

Отзывы: