DC PRE-CHARGE FAULT
PAGE
|
77
over temperature fault, lower coolant temperature below 28 °C and then cycle DC power (remove DC
power, wait 30 seconds, reapply DC power). When the RDY indicator illuminates, lasing is enabled after
the five-second delay. If the TMP indicator remains red after cycling power, continue to flow cooling
water through the laser for a few more minutes and/or verify the coolant flow rate and then cycle DC
power again.
Under Voltage fault
This fault is indicated by the RDY LED flashing 1 blink. The Laser Ready Output Opens under these
conditions. To reset an under-voltage fault, first correct the voltage problem and ensure that 48 VDC is
measured at the laser’s DC power terminals. Next, cycle DC power off and then on again. When the RDY
LED illuminates, the Laser Ready output Closes, and lasing is enabled after the five-second delay. Apply
a PWM Command signal, provided the SHT indicator is illuminated blue.
Over Voltage fault
An over voltage fault occurs when DC input voltage rises above a preset limit of 49.5 VDC. This fault is
indicated by the RDY LED flashing 2 blinks. Under these conditions the Laser Ready output Opens. To
reset an over voltage fault first correct the voltage problem and ensure 48 VDC is measured at the
laser’s DC power terminals. Next, cycle DC power off and then on again. When the RDY LED illuminates,
the Laser Ready output Closes, and lasing is enabled (after a five-second delay) provided a PWM
Command signal is applied, and the SHT indicator is illuminated blue.
RF Drive Switch fault
An RF Drive Switch fault occurs during power-up. RF drive switch faults are triggered by either of the
following: the tube fails to breakdown, or the RF Driver’s 48-volt switching circuitry fails. A RF drive
switch fault is indicated when the RDY LED flashes 3 blinks and the Laser Ready output Closes. If a RF
Drive Switch fault occurs, the laser requires service-Contact Contact NOVANTA® Customer Service or a
NOVANTA Authorized Distributor.
PWM Drive fault
A PWM Drive fault signals a problem in the laser’s internal RF circuitry and is indicated by a flashing RDY
LED that blinks 4 times. If a PWM Drive fault appears, the laser requires service— please contact
NOVANTA Customer Service or a NOVANTA Authorized Distributor.
DC Pre-Charge fault
A DC Pre-Charge fault indicates that 48 VDC is not available at the input of one or more of the RF
modules. The RDY LED will flash in a 5-blink pattern. When this occurs, the Laser Ready output Opens. If
a DC Pre-Charge fault appears, the laser requires service—please contact NOVANTA Customer Service
or a NOVANTA Authorized Distributor.
Содержание SYNRAD Pulstar p100
Страница 1: ...ENGINEERED BY SYNRAD p100 150 Lasers User Manual...
Страница 17: ...NOMENCLATURE CONTINUED PAGE 12 Nomenclature Continued Figure 1 2 Anatomy of a model number...
Страница 23: ...ADDITIONAL LASER SAFETY INFORMATION PAGE 18 p100 label locations...
Страница 24: ...ADDITIONAL LASER SAFETY INFORMATION PAGE 19 p150 label locations...
Страница 30: ...ELECTROMAGNETIC INTERFERENCE STANDARDS PAGE 25 Figure 2 1 p100 Declaration Document...
Страница 31: ...ELECTROMAGNETIC INTERFERENCE STANDARDS PAGE 26 Figure 2 2 p150 Declaration Document...
Страница 39: ...FOCUSING OPTICS PAGE 34 Table 3 1a Dew point temperatures in Fahrenheit Dew Point Table F...
Страница 46: ...OPERATION MODES PAGE 41 Figure 3 6 p150 pulse profile 37 5 duty cycle at 10 kHz...
Страница 49: ...USER I O CONNECTION SUMMARY PAGE 44 Figure 3 9 User I O connector pinouts...
Страница 68: ...REMOTE INTERLOCK FUNCTIONS PAGE 63 Figure 3 21 p100 150 outline mounting drawings pg 1 of 2...
Страница 70: ...REMOTE INTERLOCK FUNCTIONS PAGE 65 Figure 3 23 p100 150 packaging instructions...
Страница 71: ...REMOTE INTERLOCK FUNCTIONS PAGE 66 Figure 3 24 p150 outline and mounting...
Страница 78: ...OPERATIONAL FLOW CHART PAGE 73 Operational flow chart Figure 4 1 p100 150 operational flowchart...
Страница 79: ...STATUS LEDS PAGE 74 Status LEDs Table 4 2 p100 p150 Input output LED Status Signals...
Страница 88: ...This page is left blank intentionally...