INTRODUCTION SUMMARY
PAGE
|
3
Introduction summary
p100/150 Trademark, copyright, contact (service & support) information &
Nomenclature
Important Notes:
•
This Operation Manual explains operation activities related to p100/150 lasers. If you cannot
operate the unit using the information described in this manual, contact NOVANTA®
(+1.425.349.3500) or an authorized NOVANTA Distributor.
•
Lift the laser only by the mounting feet or baseplate. Do not lift or support the laser by its cooling
fittings.
•
Please reference the Quick Start Guide for unpacking, mounting, and connecting.
•
Failure to properly package the laser using NOVANTA shipping box and foam/cardboard inserts
as shown in Packaging Instructions may void the warranty. Customers may incur additional repair
charges due to shipping damage caused by improper packaging.
•
Before beginning any maintenance or inspections of your p100/150 laser, be sure to completely
disable the laser by disconnecting the DC Power cable (or cables) from the rear of the laser.
•
A risk of exposure to toxic elements may result when certain optical or beam delivery
components are damaged. In the event of damage to laser, marking head, or beam delivery
optics, contact NOVANTA, or the optics manufacturer for handling instructions.
•
If you operate your laser in dirty or dusty environments, contact NOVANTA about the risks of
doing so and precautions you can take to increase the longevity of your laser, marking head, and
associated optical components.
•
Remote interlock faults are not latched on OEM lasers. Clearing the fault condition re-enables the
RDY indicator and the laser will fire immediately provided the SHT indicator is lit and a PWM
Command signal is applied.
•
Because exposure to CO2 laser radiation in the (9-11)
µ
m range can inflict severe corneal injuries
and seriously burn human tissue, the OEM or System Integrator must ensure that appropriate
safeguards are in place to prevent unintended lasing.
•
A risk of exposure to toxic elements may result when certain op-tical or beam delivery
components are damaged. In the event of damage to laser, marking head, or beam delivery
optics, contact NOVANTA, or the optics manufacturer for handling instructions.
•
The use of the Quick Start Plug bypasses the laser’s safety inter-lock function, potentially
exposing personnel in the area to invisible infrared laser radiation. The Quick Start Plug is
intended only for initial testing and troubleshooting by qualified personnel. In normal operation,
the laser’s Remote Interlock input should be connected to the machine’s safety interlock circuitry.
Содержание SYNRAD Pulstar p100
Страница 1: ...ENGINEERED BY SYNRAD p100 150 Lasers User Manual...
Страница 17: ...NOMENCLATURE CONTINUED PAGE 12 Nomenclature Continued Figure 1 2 Anatomy of a model number...
Страница 23: ...ADDITIONAL LASER SAFETY INFORMATION PAGE 18 p100 label locations...
Страница 24: ...ADDITIONAL LASER SAFETY INFORMATION PAGE 19 p150 label locations...
Страница 30: ...ELECTROMAGNETIC INTERFERENCE STANDARDS PAGE 25 Figure 2 1 p100 Declaration Document...
Страница 31: ...ELECTROMAGNETIC INTERFERENCE STANDARDS PAGE 26 Figure 2 2 p150 Declaration Document...
Страница 39: ...FOCUSING OPTICS PAGE 34 Table 3 1a Dew point temperatures in Fahrenheit Dew Point Table F...
Страница 46: ...OPERATION MODES PAGE 41 Figure 3 6 p150 pulse profile 37 5 duty cycle at 10 kHz...
Страница 49: ...USER I O CONNECTION SUMMARY PAGE 44 Figure 3 9 User I O connector pinouts...
Страница 68: ...REMOTE INTERLOCK FUNCTIONS PAGE 63 Figure 3 21 p100 150 outline mounting drawings pg 1 of 2...
Страница 70: ...REMOTE INTERLOCK FUNCTIONS PAGE 65 Figure 3 23 p100 150 packaging instructions...
Страница 71: ...REMOTE INTERLOCK FUNCTIONS PAGE 66 Figure 3 24 p150 outline and mounting...
Страница 78: ...OPERATIONAL FLOW CHART PAGE 73 Operational flow chart Figure 4 1 p100 150 operational flowchart...
Страница 79: ...STATUS LEDS PAGE 74 Status LEDs Table 4 2 p100 p150 Input output LED Status Signals...
Страница 88: ...This page is left blank intentionally...