Code 39 Check Digit 

 

 

Use the following commands to allow scanning of all Code 39’s (No Check Digits) or only 

 

allow codes with a Check Digit. Default = No Check Digits. 

 

  

 

 

 

 

 

* Disable C39 Check Digit 

Validate, but don’t Transmit 

 

Validate and Transmit 

 

 

Code 39 Convert to Code 32 / Pharmacode 

 

 

Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan the 

 

appropriate bar code below to enable or disable converting Code 39 to Code 32. 

 

Default = Disabled. 

 

 

Note:

 

In order for this parameter to work, Code 39 must be enabled.

 

 

  

 

 

 

  

 

 

Enable 

 

 

 

 

 

 

 

* Disable 

 

 

Trioptic Code 39 

 

 

Trioptic Code 39 is a variant of Code 39 used in the marking of computer tape 

 

cartridges. Trioptic Code 39 symbols always contain six characters. To enable or  disable 

 

Trioptic Code 39, scan the appropriate bar code below. Default = Disabled. 

 

 

Note: 

You cannot enable Trioptic Code 39 and Code 39 Full ASCII simultaneously.

 

 

  

 

 

 

  

 

 

Enable 

 

 

 

 

 

 

 

* Disable

 

Содержание Jadak Flexpoint HS-1R

Страница 1: ...Flexpoint HS 1R User s Manual Page i Flexpoint HS 1R User Guide...

Страница 2: ...copyright and distributed under licenses restricting its use copying distribution and decompilation No part of this product or document may be reproduced in any form by any means without prior written...

Страница 3: ...Flexpoint HS 1R User s Manual Page iii Revision History DATE Version Description 12 13 2015 Original Original HS 1R manual 07 18 2018 07182018 Updated to new format...

Страница 4: ...ion 13 Reading Techniques 14 Chapter 2 Interface Settings Connecting the HS 1R with USB Port 15 Interface Options 16 USB COM Port Emulation 16 USB HID Keyboard Emulation 16 Keyboard Country Layout 17...

Страница 5: ...lities Utilities Overview 24 Report the list of available Programming Commands 24 Revision 24 Show Software Revision 24 Show Revision Time 24 Show Device Serial Number 24 Chapter 5 Data Editing Data E...

Страница 6: ...rite Block 30 RFID Data Text Mode 31 RFID UID Only 31 RFID Reverse UID 31 RFID Prefix 32 RFID Prefixes On Off 32 RFID Prefix Block String 32 RFID Suffix 33 RFID Suffix On Off 33 RFID Suffix Block Stri...

Страница 7: ...Chapter 8 Symbologies All Symbologies 40 Linear Symbologies 41 Codabar 41 Codabar Defaults 41 Codabar On Off 41 Codabar Minimum and Maximum Length 41 Code 11 42 Code 11 Defaults 42 Code 11 On Off 42 C...

Страница 8: ...93 On Off 47 Code 93 Minimum and Maximum Length 47 Composite Code 48 GS 1 Composite Code 48 Composite Code Minimum and Maximum Length 48 EAN 8 JAN 8 49 EAN 8 JAN 8 Defaults 49 EAN 8 JAN 8 On Off 49 E...

Страница 9: ...ix 2 of 5 Minimum and Maximum Length 53 MSI 53 MSI Defaults 53 MSI On Off 53 MSI Minimum and Maximum Length 53 MSI Check Digits 54 UPC A 55 UPC A Defaults 55 UPC A On Off 55 UPC A Check Digit 55 UPC E...

Страница 10: ...f 58 Data Matrix 58 Data Matrix Defaults 58 Data Matrix On Off 58 2D Matrix Symbologies 59 Maxi Code 59 Maxi Code Defaults 59 Maxi Code On Off 59 QR Code 59 QR Code Defaults 59 QR Code On Off 59 Chapt...

Страница 11: ...mpliance 66 FCC Class B Compliance Statement 66 Flexpoint HS 1R Series N Certificate of Conformity 68 Appendices Appendix A Command Format 69 Appendix A1 2 Command List and Standard Default Parameters...

Страница 12: ...onments The HS 1R has a sealed housing that protects it from day to day debris and spills and is built with medical grade plastics that are compatible with popular medical cleansers and disinfectants...

Страница 13: ...5 nm laser and a pattern forming element to generate a laser aiming pattern which represents the imager s field of view throughout its entire depth of field The pattern s center dot indicates the cent...

Страница 14: ...smaller when the imager is closer to the code and larger when it is farther from the code Symbologies with smaller bars or elements lower mil size should be read closer to the unit Symbologies with l...

Страница 15: ...our computer The driver is available from your JADAK technical support contact No driver is required when using the USB HID Keyboard interface 2 Turn off power to the terminal computer 3 Connect the a...

Страница 16: ...S1 R to emulate a regular RS 232 based COM port Note The HS 1R must be power cycled after programming this interface USB COM Emulation USB HID Keyboard Emulation Scan the following code to program the...

Страница 17: ...s set to USB HID Keyboard Emulation use the following commands or programming barcodes to set the specific Keyboard layout for your language Default United States United States United Kingdom Belgium...

Страница 18: ...ng the data faster or slower on a keyboard Faster settings may lead to data loss when large amounts of data are transmitted Note This setting has no impact when using the HS 1R in USB COM Emulation mo...

Страница 19: ...unit to its custom default settings Note The HS 1R must be power cycled after programming this command To set custom defaults please contact Jadak Factory Default Settings Scan the following code rev...

Страница 20: ...d When there is no code read the HS 1R may return a no read signer in the form of the characters NR Default Disable No Read Disable No Read Enable No Read Vibration The HS 1R has an optional internal...

Страница 21: ...command turns the trigger OFF Trigger Modes Manual Trigger level You can activate the imager by pressing the trigger or sending the serial trigger command TRGON When in manual trigger mode the HS 1R s...

Страница 22: ...t 1 0 seconds Trigger Time Out 5 0 seconds Trigger Time Out 9 9 seconds Trigger Time Out 30 0 seconds Good Read Delay This sets the time period before the scanner can read another bar code Use the com...

Страница 23: ...Re read Delay This sets the time period before the imager can read the same bar code a second time Setting a proper re read delay time protects against accidental re reads of the same bar code Use sh...

Страница 24: ...re about certain aspects of the HS 1 hand scanner Report the list of available Programming Commands All of the supported serial command of the imager along with a short description and the current set...

Страница 25: ...ge string The selections in this section are used to build the user defined data into the message string The following illustration shows the breakdown of a message string Transmit AIM ID Character Us...

Страница 26: ...e Barcode prefixes scan the appropriate code below Default enabled Enable Disable Barcode Prefix Block String Use the command PREBBLK in combination with ASCII or hex characters to set the specific Ba...

Страница 27: ...x Block String Use the command SUFBBLK in combination with ASCII or hex characters to set the specific Barcode Suffix string See Appendix D for ASCII hex conversion help Note Hex characters must be pr...

Страница 28: ...d RFID Reading When presenting a RFID tag to the HS 1R depending on the settings for PRERENA RFIDMIN and RFIDMAX it can automatically present the data in the following format Prefix Tag UID Block data...

Страница 29: ...0 second Setting examples RFID Time Out 1 0 seconds RFID Time Out 2 0 seconds RFID Time Out 5 0 seconds RFID Time Out 10 0 seconds RFID Re read Delay This sets the time period before the HS 1R can re...

Страница 30: ...Read Block 0 of ISO 15693 tag RFID Read Block 3 of ISO 15693 tag RFID Read Block 2 of a Topaz tag RFID Read Block 4 of MiFare Classic tag RFID Write Block The HS 1R can write data to specific blocks...

Страница 31: ...Default Enabled RFID Text Enabled RFID Text Disabled RFID UID Only The HS 1R has the option to only output the UID of a scanned tag Default disabled UID Only Enabled UID Only Disabled RFID Reverse UID...

Страница 32: ...below Default enabled Enable Disable RFID Prefix Block String Use the command PRERBLK in combination with ASCII or hex characters to set the specific RFID Prefix string See Appendix D for ASCII hex c...

Страница 33: ...ing Use the following command in combination with ASCII or hex characters to set the specific RFID Suffix string See Appendix D for ASCII hex conversion help Note Hex characters must be preceded by x...

Страница 34: ...but you can also have the HS 1R switch back to barcode presentation mode from RFID mode after a specific time Use the command PSTTIME x where x is a value between 0 and 3600000 to set the time betwee...

Страница 35: ...ed externally by a host This can be useful for certain notifications Five different beeper tones are available in the HS 1R Use the command LEDINDC x where x is a value between 0 and 4 to have the HS...

Страница 36: ...re several options to configure the HS 1R for improved barcode finding and decoding that are related to image processing This chapter describes these options Illumination Brightness Use the command LE...

Страница 37: ...by sending the serial command EXP_MAX x where x is a value between 1 and 7874 or by building a menu command barcode Please contact JADAK if assistance is needed Default value 100 Setting examples Targ...

Страница 38: ...t Disabled Enable Decode Windowing Disable Decode Windowing To define the Decode Window one needs to set the boundaries for Top Bottom Left and Right These boundaries are defined by pixel values withi...

Страница 39: ...0 and 843 or by building a menu command barcode Default Left boundary 338 Default Right boundary 506 Please contact JADAK if assistance is needed This is a screenshot of an example where a Decode Wind...

Страница 40: ...9 Maxi Code Code 93 MicroPDF417 Composite Code MSI Data Matrix PDF417 EAN JAN 13 QR Code EAN JAN 8 UPC A GS1 128 UPC E GS 1 Databar RSS 14 UPC E1 All Symbologies If you want to be able to decode all t...

Страница 41: ...inimum and Maximum Length Use the following commands in combination with numerical values to set the minimum and maximum length Default minimum length 4 Default maximum length 55 The minimum and maxim...

Страница 42: ...m and Maximum Length Use the following commands in combination with numerical values to set the minimum and maximum length Default minimum length 4 Default maximum length 55 The minimum and maximum le...

Страница 43: ...The HS 1R may look for a check digit to decide if the code is valid Code 11 usually has 1 check digit and some codes have 2 check digits Either option can be chosen to be validated Default 1 Check Dig...

Страница 44: ...lt minimum length 0 Default maximum length 55 The minimum and maximum length for this barcode can be set either by sending the serial command shown under the barcodes below with a value between 0 and...

Страница 45: ...ult minimum length 0 Default maximum length 48 The minimum and maximum length for this barcode can be set either by sending the serial command shown under the barcodes below with a value between 0 and...

Страница 46: ...lian pharmaceutical industry Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32 Default Disabled Note In order for this parameter to work Code 39 must be enabled En...

Страница 47: ...d Maximum Length Use the following commands in combination with numerical values to set the minimum and maximum length Default minimum length 0 Default maximum length 55 The minimum and maximum length...

Страница 48: ...e Composite Code Minimum and Maximum Length Use the following commands in combination with numerical values to set the minimum and maximum length The minimum and maximum length for this barcode can be...

Страница 49: ...this code EAN 8 JAN 8 On Off Scan one of the codes below to enable or disable EAN 8 Default Enabled Enable Disable EAN 13 JAN 13 EAN 13 JAN 13 Defaults Set the EAN 13 settings to their default configu...

Страница 50: ...14 Scan one of the codes below to enable or disable GS1 DataBar Default Enabled Enable Disable GS1 DataBar Limited Formerly RSS Limited Scan one of the codes below to enable or disable GS1 DataBar Lim...

Страница 51: ...aved 2 of 5 Minimum and Maximum Length Use the following commands in combination with numerical values to set the minimum and maximum length Default minimum length 6 Default maximum length 30 The mini...

Страница 52: ...ation Check digit can be validated and if desired transmitted too Default Disabled Disable I 2 of 5 Check Digits USS Check Validate USS Check Validate Transmit Matrix 2 of 5 Matrix 2 of 5 Defaults Set...

Страница 53: ...nd barcode Default minimum length 4 Default maximum length 55 Please contact JADAK if assistance is needed Matrix 2 of 5 Minimum Length Matrix 2 of 5 Maximum Length MSI MSI Defaults Set all MSI settin...

Страница 54: ...k Digits With MSI symbols one check digit is mandatory and always verified by the reader The second check digit is optional If the MSI codes include two check digits scan the Two MSI Check Digits bar...

Страница 55: ...disable UPC A Default Enabled Enable Disable UPC A Check Digit The check digit is the last character and is used to verify data integrity This digit is always checked but it may be chosen whether or...

Страница 56: ...git is always checked but it may be chosen whether or not to transmit it Default Transmit Transmit UPC E Check Do Not Transmit UPC E Check UPC E 0 Expanded ModeOn Off UPC E 0 Expanded Mode expands the...

Страница 57: ...scan this code PDF417 On Off Scan one of the codes below to enable or disable PDF417 Default Enabled Enable Disable MicroPDF417 MicroPDF417 Defaults To set the default values for Micro PDF417 scan th...

Страница 58: ...ode scan this code Aztec Code On Off Scan one of the codes below to enable or disable Aztec Code Default Enabled Enable Disable Data Matrix Data Matrix Defaults To set the default values for Data Matr...

Страница 59: ...or Maxi Code scan this code Maxi Code On Off Scan one of the codes below to enable or disable Maxi Code Default Disabled Enable Disable QR Code QR Code Defaults To set the default values for QR Code s...

Страница 60: ...ees Motion Tolerance Up to 230 inches 584 cm per second Scan Contrast 45 minimum for Matrix codes 20 minimum reflectance for 1D codes Voltage Requirements 4 50 5 25 VDC at scanner connector input Curr...

Страница 61: ...expoint HS 1R User s Manual Page 61 Standard Cable Pin out USB 1 2 Data 10 Pin Modular Plug 3 Tied to 5 volt power connects to the imager handle 4 Supply ground 5 6 7 5 volt power connection 8 9 10 Da...

Страница 62: ...ent solution is used rinse with a clean lens tissue dampened with water only Cleaning the Scanner Housing The HS 1R is IP54 rated when the cable is attached This means that liquids and dusts will not...

Страница 63: ...to the host system OFF 2 Disconnect the imager s cable from the terminal or computer 3 Locate the small hole underneath a triangular label on the bottom side of the hand scanner near the cable connec...

Страница 64: ...py of the dated purchase record attached Contact the appropriate location below to obtain a Return Material Authorization number RMA before returning the product If you need assistance installing or t...

Страница 65: ...e except for return shipping to JADAK EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR WARRANTIES EITHER EXPRESSED OR IMPLIED ORAL OR W...

Страница 66: ...that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off an...

Страница 67: ...Flexpoint HS 1R User s Manual Page 67 FCC ID 2AAVI HS1RN4 IC 11355A HS1RN4...

Страница 68: ...0950 1 2006 a11 2009 a1 2010 ITE Safety Part 1 IEC 62471 2008 LED Safety note LED s are not covered by IEC EN 60825 1 second edition RSS GEN Issue 4 November 2014 Radio Standards Specification RSP 100...

Страница 69: ...n the following pages as well as a brief description of what the parameter choices mean Some commands require further elaboration that can be found in the relevant sections in the guide For example th...

Страница 70: ...vice s current ROM value for the setting What is the device s current RAM value for the setting What is the range of possible values for the setting Examples In the following examples a bracketed nota...

Страница 71: ...N A N A C39ASCI Code 39 Full ASCII Mode 0 0 0 0 1 C39CHEC Code 39 Check Digit 0 none 1 req 2 req xmit 0 0 0 0 1 2 C39ENAB Enable Code 39 Decoding 1 1 1 0 1 C39MAXL Max Code 39 Symbol Length 48 48 48 0...

Страница 72: ...Enable conversion C39 to C32 Pharma C39DEFA Default Code 39 parameters C39ENAB 0 to 1 1 Enable Code 39 Decoding C39MAXL 0 to 48 48 Max Code 39 symbol length C39MINL 0 to 48 0 Min Code 39 symbol length...

Страница 73: ...2of5 Decoding I25MAXL 0 to 55 30 Max I2of5 Symbol Length I25MINL 0 to 55 6 Min I2of5 Symbol Length IMGMAXX 844 Get Image Width IMGMAXY 640 Get Image Height ISBT128 0 to 1 0 Enable ISBT 128 Concatenati...

Страница 74: ...TRGOFF Software Trigger Off TRGON Software Trigger On TRGTIME 0 to 300000 9900 Trigger Timeout in milliseconds UE1ENAB 0 to 1 0 Enable UPC E1 Decoding UPADEFA Default UPC A parameters UPAENAB 0 to 1 1...

Страница 75: ...iseconds RFIDDLY 0 to 5000 1000 RFID Re Read Delay in Milliseconds RFIDMIN 0 to 255 0 RFID Start Read Block Number RFIDMAX 0 to 255 7 RFID End Read Block Number RFIDMOD 0 to 2 0 RFID Mode 0 Off 1 On R...

Страница 76: ...st symbol character position 2 Function code 1 in second symbol character position Example A Code EAN 128 bar code with Function 1 character FNC1 in the first position AIMID is transmitted as C1AIMID...

Страница 77: ...check digit Example An I 2 of 5 bar code without check digit 4123 is transmitted as I04123 PDF417 Macro PDF417 Micro PDF417 L 0 Reader set to conform to protocol defined in 1994 PDF417 Symbology spec...

Страница 78: ...0 No options specified at this time Always transmit 0 Example A D 2 of 5 bar code 4123 is transmitted as S04123 Maxicode U 0 Symbol in Mode 4 or 5 1 Symbol in Mode 2 or 3 2 Symbol in Mode 4 or 5 ECI p...

Страница 79: ...Flexpoint HS 1R User s Manual Page 79 Appendix C Sample Bar Codes UPC A Codabar Code 128 Code 39 Code 93 Interleaved 2 of 5 PDF 417 Composite Code MicroPDF Aztec Data Matrix QR Code MaxiCode...

Страница 80: ...48 H 104 68 h 9 09 HT 41 29 73 49 I 105 69 i 10 0A LF 42 2A 74 4A J 106 6A j 11 0B VT 43 2B 75 4B K 107 6B k 12 0C FF 44 2C 76 4C L 108 6C l 13 0D CR 45 2D 77 4D M 109 6D m 14 0E SO 46 2E 78 4E N 110...

Страница 81: ...38 8A 170 AA 202 CA 234 EA 139 8B 171 AB 203 CB 235 EB 140 8C 172 AC 204 CC 236 EC 141 8D 173 AD 205 CD 237 ED 142 8E 174 AE 206 CE 238 EE 143 8F 175 AF 207 CF 239 EF 144 90 176 B0 208 D0 240 F0 145 9...

Страница 82: ...JADAK HS 1R UM 07182018...

Отзывы: