Flexpoint™ HS-1R User’s Manual
Page 29
RFID Time Out
This sets the time out period for RFID read and write operations. If such an operation does not
take place within the programmed period, a time out message will be sent by the HS-1R.
Several commonly used RFID Time Out menu command barcodes are included below.
Use the command
RFIDTMO
x
(where ‘x’ is a value between 0 and 65535)
, to set the time
between 0 (no delay) and 65535 (=~65.5 seconds) in steps of 1ms, or by building a menu
command barcode.
Please contact JADAK if assistance is needed. Default time = 1000 (1.0 second).
Setting examples:
* RFID Time Out 1.0 seconds
RFID Time Out 2.0 seconds
RFID Time Out 5.0 seconds
RFID Time Out 10.0 seconds
RFID Re-read Delay
This sets the time period before the HS-1R can read the same RFID tag a second time.
Setting a proper re-read delay time protects against accidental re-reads of the same tag.
Several commonly used re-read delay menu command barcodes are included below. Use the
command
RFIDDLY
x
(where ‘x’ is a value between 0 and 5000)
, to set the time between 0 (no
delay) and 5000 (=5 sec.) in steps of 1ms, or by building a menu command barcode.
Please contact JADAK if assistance is needed. Default time = 1.0 seconds.
Setting examples:
No Re-read delay
Re-read delay 0.5 seconds
* Re-read delay 1.0 seconds
Re-read delay 2.0 seconds