21
Environmental Conditions
IMS-MN-LMDE42C_A
Liberty MDrive Ethernet TCP/IP
Vibration and Shock
Vibration, sinusoidal
m/s
2
10
IEC 60721-3-2
Shock, non-sinusoidal
m/s
2
100
IEC 60721-3-2
EMC
Emission
EIC61800-3 (Category C2)
Noise immunity
IEC61000-6-2
IP Degree of Protection
The product has the following IP degree of protection as per EN 60529.
Motor Style
NEMA 17 (42 mm)
Rotary
IP20/IP65
1
Linear Actuators
IP20
Electric Cylinders
IP20
1
Motor shaft is not sealed. To meet an IP65 rating, ensure that the NEMA flange of the motor is properly sealed.
The total degree of protection is determined by the component with the lowest degree of
protection.
NOTICE
INOPERABLE EQUIPMENT
Ensure that the NEMA flange of the motor is properly sealed for any LMD Rotary M12 connector
products used in IP65 rated applications.
Failure to follow these instructions can result in equipment damage.