51
Signal Input Circuits
IMS-MN-LMDE42C_A
Liberty MDrive Ethernet TCP/IP
Pin
MD-CS610 Wire
Signal
Function
I/O
1
Brown
IN4
General purpose programmable Input 4
I
2
Blue
IN2
General purpose programmable Input 2
I
3
White
INPUT_REF
Biases the input as sinking or sourcing
I
4
Green
N/C
Not connected
—
5
Pink
IN3
General purpose programmable Input 3
I
6
Yellow
ANALOG_IN
Analog input
I
7
Black
LOGIC_GND
Logic ground (non-isolated)
—
8
Gray
SIGNAL_OUTPUT_
EMITTER
High-speed signal output emitter
O
9
Red
SIGNAL_OUTPUT_
COLLECTOR
High-speed signal output collector
O
10
Violet
N/C
Not connected
—
11
Gray/Pink
N/C
Not connected
—
12
Red/Blue
N/C
Not connected
—
Connector Style
: 12-position M12 (male) A-Coded
Recommended cable/cordset
: M12 Signal Cable - Straight, 9.8ft (3m) length, flying leads to 12-position
M12 (female) A-Coded (IMS part number - MD-CS610-000)
Wiring/Cable Specifications
• Shielded cable
• Twisted-pair cables
• Grounding of the shield at both ends, only if on the equipotential ground plane.
Max cable length
1
feet (m)
328 (100)
Minimum conductor cross section
AWG (mm
2
)
24 (0.205)
Maximum conductor cross section
AWG (mm
2
)
20 (0.518)
1
The length depends on the conductor cross section and the driver circuit used
• Use equipotential bonding conductors.
• Verify that wiring, cables, and connected interfaces meet the PELV requirements.