SERVICE BULLETIN
Note No.
SVC-FSB-0050
Release Date
11/20/2017
Contact
© 2017 Cutting Edge Optronics, Inc.
5
SVC-FSB-0050 Iklwa II and Patara II
Shutter Assembly Repair Procedure
Figure 6: No Gap Causing Interference
Figure 7: Has Gap – No Interference
2.6.
There are a couple of options to repair this.
a.
Remove the shutter assembly from the laser.
b.
Using a 3/16" nut driver, loosen the nuts holding the solenoid to the mount.
These nuts are located on the back side of the mount. If possible, slide the
solenoid up in the mount and tighten the nuts. Test to see if the bottom of the
arm is still binding to the bench.
Figure 8: Rear of Shutter Assembly
GOOD: Sufficient gap;
will not contact or
bind on bench
BAD: No gap and
potential to contact and