SERVICE BULLETIN
Note No.
SVC-FSB-0050
Release Date
11/20/2017
Contact
© 2017 Cutting Edge Optronics, Inc.
2
SVC-FSB-0050 Iklwa II and Patara II
Shutter Assembly Repair Procedure
1.2.
Wipe off the outside of the laser.
1.3.
Put on powder free gloves.
1.4.
Ensure power is turned off to the laser and unplug laser from power source.
1.5.
Using a 3/32" hex driver, loosen the mounting hardware holding the laser cover to the
laser housing.
1.6.
Remove the cover.
2.
Determine Failure Mechanism and Repair
Shutter assemblies shipped in lasers prior to May 2017 may encounter interference between
screws protruding through the disk and the solenoid when the shutter is in the open position.
See
Figures 1
and
2
below.
Figure 1: Protruding Screw
Figure 2: Protruding Screw – Close Up
2.1.
Ensure that none of the three mounting screw ends are visible between the solenoid
body and the thin disk, as seen in
Figures 1
and
2
above.
Screw Head Protruding
Causing Shutter to Bind
Screw Head Protruding
Causing Shutter to Bind
Disk
Solenoid