background image

 

SERVICE BULLETIN

 

Note No. 

SVC-FSB-0050 

Release Date 

11/20/2017 

Contact 

[email protected]

 

 

© 2017 Cutting Edge Optronics, Inc.  

SVC-FSB-0050 Iklwa II and Patara II 

Shutter Assembly Repair Procedure 

2.2.

 

Using gloved hands, place a finger atop the shutter arm, rotating clockwise while 
pushing the arm toward the solenoid as if trying to open the shutter. Feel for any 
binding that may occur.  

2.3.

 

Inspect the hardware used to mount the arm to the solenoid. Verify that each of the 
three mounting screws has both a lock and a flat washer. See 

Figure 3

 

Figure 3: Inspect Mounting Hardware 

 

2.4.

 

If the screw ends are visible between the disk and the solenoid, if any binding is 
observed when manually opening the shutter, or there is missing hardware on the 
screws, cut the cable tie shown below and disconnect the 4-pin connector.  Remove 
the shutter assembly from the laser.  Remove the three sets of mounting hardware 
holding the arm into place. Ensure the screws are 1/4" long. Verify there is a lock and 
flat washer on each screw and re-attach arm with the mounting hardware.  Re-install 
the shutter assembly back into the laser.  Connect the 4-pin connector. Using a cable 
tie, tie the wire to the bench.   

Содержание Iklwa II

Страница 1: ...t hardware or incorrect arm alignment Scope This service bulletin applies to shutter assemblies in Iklwa II and Patara II lasers manufactured prior to July 11 2017 Responsibilities The NG CEO Technical Service Department is responsible for the content of this service bulletin Safety Requirements CAUTION Ensure the laser is turned off and unplugged from the electrical source prior to performing thi...

Страница 2: ...laser cover to the laser housing 1 6 Remove the cover 2 Determine Failure Mechanism and Repair Shutter assemblies shipped in lasers prior to May 2017 may encounter interference between screws protruding through the disk and the solenoid when the shutter is in the open position See Figures 1 and 2 below Figure 1 Protruding Screw Figure 2 Protruding Screw Close Up 2 1 Ensure that none of the three m...

Страница 3: ...rews has both a lock and a flat washer See Figure 3 Figure 3 Inspect Mounting Hardware 2 4 If the screw ends are visible between the disk and the solenoid if any binding is observed when manually opening the shutter or there is missing hardware on the screws cut the cable tie shown below and disconnect the 4 pin connector Remove the shutter assembly from the laser Remove the three sets of mounting...

Страница 4: ...onics Inc 4 SVC FSB 0050 Iklwa II and Patara II Shutter Assembly Repair Procedure Figure 4 Inspect Mounting Hardware 2 5 Shutter assemblies shipped in lasers prior to July 2017 may encounter interference between the bottom of the arm and the laser bench See Figures 5 7 below Figure 5 Area of Detail Area of Detail ...

Страница 5: ...couple of options to repair this a Remove the shutter assembly from the laser b Using a 3 16 nut driver loosen the nuts holding the solenoid to the mount These nuts are located on the back side of the mount If possible slide the solenoid up in the mount and tighten the nuts Test to see if the bottom of the arm is still binding to the bench Figure 8 Rear of Shutter Assembly GOOD Sufficient gap will...

Страница 6: ...h proper hardware d Reinstall the shutter assembly back into the laser Connect the 4 pin connector Using a cable tie secure the wire to the bench Test to see if the bottom of the arm is still binding to the bench Figure 9 Remove Shutter Arm and File or Grind Bottom Edge and Corner 3 Inspect Laser and Replace Cover 3 1 Once there is no binding with the shutter clean the inside of the laser of any d...