SERVICE BULLETIN
Note No.
SVC-FSB-0050
Release Date
11/20/2017
Contact
© 2017 Cutting Edge Optronics, Inc.
6
SVC-FSB-0050 Iklwa II and Patara II
Shutter Assembly Repair Procedure
c.
Remove the hardware holding the arm in place. File or grind material off of
the bottom and corner of the arm. Reattach arm to solenoid with proper
hardware.
d.
Reinstall the shutter assembly back into the laser. Connect the 4-pin
connector. Using a cable tie, secure the wire to the bench. Test to see if the
bottom of the arm is still binding to the bench.
Figure 9: Remove Shutter Arm and File or Grind Bottom Edge and Corner
3.
Inspect Laser and Replace Cover
3.1.
Once there is no binding with the shutter, clean the inside of the laser of any debris.
3.2.
Replace the cover and tighten all of the mounting hardware.
3.3.
Return the laser to normal operation.
File or grind
these edges