![Northern Lights M150A13 Скачать руководство пользователя страница 84](http://html1.mh-extra.com/html/northern-lights/m150a13/m150a13_operators-manual_1708512084.webp)
OM3-80 12/21
Troubleshooting (Continued)
OUOD006,0000113 -19-16OCT07-5/5
Symptom
Problem
Solution
Engine overloaded.
Reduce load.
Improper valve clearance.
See your authorized servicing dealer
or engine distributor.
Injection nozzles dirty.
See your authorized servicing dealer
or engine distributor.
Injector tip deposits
Use John Deere approved biodiesel
fuel conditioners containing
detergents.
Engine out of time.
See your authorized servicing dealer
or engine distributor.
Defective turbocharger.
See your authorized servicing dealer
or engine distributor.
Low engine temperature.
Check thermostat.