OM3-80 12/21
Engine Operation (Continued)
RG19661,00003BC -19-28FEB13-2/5
RG19661,00003BC -19-28FEB13-3/5
Continued on next page
RG19661,00003BC -19-28FEB13-4/5
IMPORTANT: DO NOT add makeup oil until the oil
level is BELOW the ADD mark on dipstick.
John Deere Engine Break-In Oil (TY22041)
should be used to make up any oil consumed
during the break-in period.
3. Check engine oil level more frequently during engine
break-in period. If oil must be added during this period,
John Deere Engine Break-In Oil is preferred. See
ENGINE BREAK-IN OIL, in Fuels, Lubricants, and
Coolant Section.
IMPORTANT: DO NOT use PLUS-50® Engine Oil
during the break-in period of a new engine or
engine that has had a major overhaul. PLUS-50
oil will not allow a new or overhauled engine to
properly wear during this break-in period.
RG8028A —UN—15JAN99
Check Engine Oil
A—Crosshatch Pattern On
Dipstick
the FULL mark, whichever is present. Oil levels
anywhere within the crosshatch are considered
in the acceptable operating range.
PLUS-50 is a trademark of Deere & Company
ENGINE OIL AND FILTER in Lubrication and
Maintenance/250 Hour Section.) Fill crankcase with
seasonal viscosity grade oil. (See DIESEL ENGINE
OIL, in Fuels, Lubricants, and Coolant Section.)
NOTE: Some increase in oil consumption may be
expected when low viscosity oils are used.
Check oil levels more frequently.
If air temperature is below -10°C (14°F), use
an engine block heater.
RG22045
—UN—29NOV12
Remove Oil Filter
A—Oil Filter
A
6. Watch coolant temperature gauge (A) closely.
If coolant temperature rises above maximum
coolant temperature (see GENERAL ENGINE
load on engine. Check sea (raw) water strainer
for plugging on heat exchanger engines. Unless
temperature drops quickly, stop the engine and
determine the cause before resuming operation.
A—Coolant Temperature
Gauge
RG1313
3—
UN—07OCT03
Coolant Temperature Gauge - Electronically Controlled Engine
Generator Set Power Units
operation when needed, start engine and run at rated
speed (with 50%—70% load) for 30 minutes every 2
weeks. DO NOT allow engine to run extended period of
time with no load.
15
IMPORTANT:
Do not add makeup oil until the oil level is BELOW the
ADD mark on the dipstick. Factory provided break in oil
required.
3. Check engine oil more frequently during engine break-
in period. If oil must be added during this period, factory
provided break-in oil is preferred. See ENGINE BREAK-IN
oil in Fuels, Lubricants, and Coolant Section.
IMPORTANT: do not use PLUS-50® Engine Oil during
the break-in period of a new engine or an engine that has
had a major overhaul. PLUS-50 oil will not allow a new or
overhauled engine to properly wear during this break-in
period.
DO NOT fill above the crosshatch pattern
of the engine oil dipstick or the FULL
mark, whichever is present. Oil levels
anywhere within the crosshatch are
considered in the acceptable operating
range.
4. GENERATOR SET POWER UNITS
To assure that your engine will deliver efficient
generator operation, start engine and run at rated
load (50% - 70% load) for 30 minutes every two
weeks. DO NOT allow the engine to run extended
period of time with no load.
5. After the first 100 hours (maximum), change engine
oil and replace engine oil filter (A). (See CHANGE
OIL AND FILTER in Lubrication and Maintenance
250/hour section). Fill crankcase with seasonal
viscosity grade oil. (See DIESEL ENGINE OIL, in
Fuels, Lubricants and Coolant Section).
NOTE: Some increase in oil consumption may be expected when low viscosity oils are used. Check oil
levels more frequently when using low viscosity oil).
If air temperature is below -10
o
C (14
o
F), use an engine block heater.