Extension Cords
Using extension cords may reduce the life of the motor. Instead, place the machine near a power source. If
you must use an extension cord:
For 110V, use at least a 12 gauge cord that does not exceed 32.8 feet in length.
For 220V, use at least a 16 gauge cord that does not exceed 32.8 feet in length.
The extension cord must have a ground wire and plug pin.
ELECTRIC PARTS LIST
155793 110 & 220 V Wiring Diagram
NAME
CONTACTOR
HEAT RELAY
TRANSFORMER
BREAKER
LIMIT SWITCH
START
STOP
COOLANT ON/OFF
E.S.P.
MAIN MOTOR
COOLANT PUMP
TYPE AND SPECIFICATION
CN-6 3A1A A C24V
RHN-5 2.4-3.6A
JBK5-40VA 400/24V
DZ47-63 1P 1A
QKS7 6070202202
XB2-BA31
XB2-BA41
XB2-BD21
XB2-BX42
400V 50HZ 3PH 0.75KW 1420R/MIN
SERIAL NO.
1
2
3
4
5
6
7
8
9
TA10
1M11
QUANTITY
2
1
1
1
1
1
1
1
1
1
1
CODE
KM
FR
TC
QF
SQ
SB1
SB2
SA
TA
M1
M2
8 OF 15