background image

 

 
WARNING! After an adaptation to a different gas please remember to: 

 

  Apply an indelible sticker on the technical data plate with the data of the new installation. 

  Fix the new seals on the regulated parts (primary air bushes, nozzles and by-pass screws). 

  Perform a pressure test of the gas circuit and check for leaks. 

  Control  the  right  working  of  the  water  grill  according  to  these  instructions.  Verify  the  good  cross 

lighting of main burners, stability and aspect of the flames. 

 

 

3.7 

Interventions, repairs and replacements (only for authorized technicians) 

 

Even  if  the  appliance  is  used  correctly,  some  problems  may  arise  for  various  reasons.  The  table  that 
follows mentions some possible problems and some suggestions to put them right.  
CAUTION !!!!  

 

  Before performing any intervention of maintenance, reparation or simple cleaning of the appliance it 

is necessary to close the gas supply gate valve at the top of the appliance. 

  At the end of every intervention of reparation or maintenance to some parts of the appliance relate to 

gas, make sure that there are no leaks or losses.  

 
Table 2 

PROBLEM 

POSSIBLE CAUSES 

Gas Smell 

Possible gas loss. 

Check external pipes and connections.  

Smell of non-burner gas 

Check that the combustion is regular.  
Check that the consumption of gas is not excessive.  
Check that there  are not obstructions  in  the encircled of the  warm 
smokes.  
Check that aspirant and area ventilation are operating property.  

‘Explosions ' in the burners 

Check the pressure of the gas.  

The pilot burner does not alight. 

Ignition  plug  is  faulty,  out  of  place  or  its  electrical  wire  is 
disconnected. 
Insufficient gas pressure. 
Pilot nozzle is obstructed. 
Gas tap is faulty.

 

The pilot burner flame does not keep alight. 

Thermocouple  is  faulty,  it  is  not  well  licked  up  and  heated  by  the 
pilot flame. 

The main burner is not ignited 

Check  that  there  is  no  leak  in  the  gas  supply  or  any  problem  with 
the nozzle.  
Check the components of the burner are well positioned.  

Main burners flames are yellow. 

Primary air bushes are adjusted in a wrong way. 
Burner is dirty. 

 
Components replacements: 
 
To replace faulty components it is necessary to remove cooking grids, radiant elements, water drawers 
and frontal and back panels. If necessary, we suggest to overturn the grill. Replacing components, such 
as the thermocouple, candle of lighting, is simple and intuitive after having removed the base wall. 
 

  In order to operate on the valve, all it takes is removing the handle grip, and the frontal panel.  

  For the substitution of the valve it is necessary to unscrew the connections in the following order: 

First the connection of the thermocouple. 

Then the connection of the gas outlet exit gas. 

Finally; the connection of entrance gas. 

 
Each main burner is equipped with the following safety device: 

  Safety thermocouple: in case of pilot flame extinction, the thermocouples cool down and cut off the 

gas  supply  to  the  main  burner.  The  safety  thermocouple  is  positioned  in  the  pilot  group  and 
connected to the rear part of gas valve (gas tap). 

 
 

Содержание GR150

Страница 1: ...EATED WATER GRILL Models GR400 GR200 GR150 GR80 Category II2H3 Installation type A1 0705 i SOTIRIOS D PRODANAS C O PROFESSIONAL ELECTRIC GAS EQUIPMENT FOR RESTAURANTS PATISSERIES SNACK BARS NATIONAL ROAD KILKIS THESSALONIKI P C 61100 GALLIKOS KILKIS CROSSROADS P O BOX 40070 P C 56404 TEL 30 23410 41991 41819 FAX 30 23410 41539 email info north gr Http www north gr ...

Страница 2: ...sure and nominal heat input controls 3 6 Adaptation to a different gas 3 6 1 Replacing the main nozzle and adjusting its primary air 3 6 2 Replacing the pilot nozzle and adjusting its primary air 3 6 3 Adjusting the minimum rate on gas valve through the by pass screw 3 7 Interventions repairs and replacements 4 INSTRUCTIONS FOR USING THE WATER GRILL for the user Page 10 4 1 Preliminary warnings be...

Страница 3: ... valid for the water grill described in this manual relevant to category II2H3 for Great Britain If the appliance is sold in a different European country with different category pressure and gases reported on the specifications data plate the manual shall be translated into the official language with the references gas connections and local installation regulations of that country Producer is resp...

Страница 4: ...dard EN ISO 228 1 2 2 Technical data plates On the back of appliance there is a technical plate Fig 1 and gas setting plate Fig 2 reporting the current gas setting nominal data of grill and a table with gases categories and pressures for all the other EC countries There is also a warning plate expressed in the language of the country of destination Fig 3 A third plate with warning and current sett...

Страница 5: ...vacuating the products of combustion to the outside of the room in which the appliance is installed The combustion air and the burned gases evacuation take place in the same room in which the appliance is installed However the appliances must be installed in places appropriate for the removal of fumes according to installation specifications Our grills are considered see technical data table as ap...

Страница 6: ...age occurs testing along the whole gas circuit and using leak finder sprays or other non corrosive foams do not use direct flames to look for leaks The burners are manufactured with a way to stand thermal and mechanical stress and are equipped with fixed nozzles This is why it is necessary to change the nozzles every time you change the type of gas Data concerning the appliance setting are to be f...

Страница 7: ...ce to technical data of table 3 replace the main nozzles the pilot nozzles adjust correctly the primary air of bush and then adjust the by pass screws on gas tapes to set the right rate at the reduced heat input Spare nozzles are provided with the appliance on its delivery or can be ordered near the seller Make sure that the diameter is printed on each nozzle in 1 100ths of a millimetre Only adapt...

Страница 8: ... replace all the components in the reverse order 3 6 3 Adjusting the minimum rate on gas valve through the by pass screw The nozzle of the valve by pass screw has a hole of 1 10 mm Ø and for the gas G30 G31 must be fully screwed down Procced in the same way for each burner For the other gases G20 and G25 the by pass screw must be unscrewed for 1 complete round turning the screw anti clockwise unti...

Страница 9: ... are operating property Explosions in the burners Check the pressure of the gas The pilot burner does not alight Ignition plug is faulty out of place or its electrical wire is disconnected Insufficient gas pressure Pilot nozzle is obstructed Gas tap is faulty The pilot burner flame does not keep alight Thermocouple is faulty it is not well licked up and heated by the pilot flame The main burner is...

Страница 10: ...water grill only to cook food Do not use it for different purposes because any other use is considered improper and dangerous Control the grill when operating Check the regular lighting of the main burner and verify the stability of the flames passing from the maximum to the minimum setting Blue color of flames is an indication of good combustion Before employing the grill for the first time clean...

Страница 11: ...specific oil If such an accurate observance of the contained instructions in this manual are observed NORTH appliances will allow perfect use and performances for a long time The manufacturer cannot be held responsible for any damage caused to property human beings or animals due to misuse of the appliances or non observance of instructions included in this manual 4 4 Technical data table and pres...