Chapter 6 R2MFC MBM maintenance
NN40010-300
Figure 28
Upgrading firmware overview
Perform the following steps to download the firmware the R2MFC MBM:
1
Copy the firmware load file and the PC program files,
bload1.exe
, to the same directory on the
PC.
2
Use the shipped cable, part number N0026100, to connect a PC to the RS-232 port on the
faceplate of the R2MFC MBM through COM1.
3
Open a new Hyper-terminal session on the PC using the parameters listed in
Table 16
.:
4
Go to step
11
if the existing firmware is corrupted. Corrupted firmware is indicated if the
BOOT program displays:
load, switch, fload, fswitch, checksum, DisMem, DisWord, *=quit
----> user monitor:
5
Wait for the monitor line (flashing cursor) to appear on the terminal session.
Table 16
Hyper-terminal setup parameters
Parameter
Setting
Connect using
COM 1
Bits per second
19 200
Data bits
8
Parity
None
Stop Bits
1
Flow Control
None
Firmware Upgrade
Required
Copy the firmware load
and PC program files to
PC
Connect PC to the
R2FMC MBM
Open a Hyper-terminal
session to connect to
R2FMC MBM
Disable links
Prepare R2FMC MBM for
upload
Verify the version of
new firmware
Check the module to see
if it is working properly
Disconnect PC from
R2FMC MBM
Is f irmware
corrupted?
Upload new firmware
file
Y es
No
Содержание R2MFC
Страница 12: ...12 NN40010 300 ...
Страница 14: ...14 How to Get Help NN40010 300 ...
Страница 20: ...20 Chapter 1 Getting started NN40010 300 NN40010 300 ...
Страница 26: ...26 Chapter 2 Overview NN40010 300 ...
Страница 72: ...72 Chapter 6 R2MFC MBM maintenance NN40010 300 ...
Страница 90: ...90 Chapter 7 Command Line Interface CLI NN40010 300 ...
Страница 108: ...108 Configuring DIP switch settings and definitions NN40010 300 ...
Страница 110: ...110 Diagnostic and loopback DIP switch settings NN40010 300 ...
Страница 112: ...112 MFC Signal Definitions NN40010 300 ...
Страница 114: ...114 CLI Cable Pinout NN40010 300 ...