61
R2MFC Media Bay Module Installation and Configuration Guide
Chapter 6
R2MFC MBM maintenance
This chapter describes the general maintenance of the R2MFC MBM after it is installed and is
running properly. It includes the following sections:
•
Inter-working functionality
•
“Clock synchronization” on page 62
•
“Diagnostic tools” on page 63
•
“Alarms” on page 64
•
“Faceplate LEDs” on page 66
•
“Logs and traces” on page 67
•
“Error messages” on page 67
•
“Replacing an R2MFC MBM” on page 68
•
“Upgrading firmware” on page 69
Inter-working functionality
All channels on both sides of the R2MFC MBM are bidirectional: they accept both incoming and
outgoing calls. If unidirectional trunks are used, the direction is handled by the far ends (BCM and
CO); the direction need not be configured in the R2MFC MBM.
In order to handle bidirectional calls, and eliminate internal collisions (when both sides originate a
call on the same channel simultaneously), the R2MFC MBM allows flexible channel
inter working; calls originating on a channel can use any free channel on the opposite side.
On incoming calls to the BCM, the far-end (for example, CO switch) selects the MFC channel.
The R2MFC MBM presents the call to the BCM by PRI and allows the BCM to determine which
channel to use.
On outgoing calls, the BCM selects on which PRI channel the call starts. The R2MFC MBM
selects a free MFC channel, and originates the outgoing call on it. For this purpose, the R2MFC
MBM supports 3 search methods to select a free MFC channel:
•
Round robin (default)
•
Linear ascending
•
Linear descending
The MFC channel selection method can be modified through the CLI. See
Chapter 7, “Command
Line Interface (CLI),” on page 73
for commands available through the CLI.
Содержание R2MFC
Страница 12: ...12 NN40010 300 ...
Страница 14: ...14 How to Get Help NN40010 300 ...
Страница 20: ...20 Chapter 1 Getting started NN40010 300 NN40010 300 ...
Страница 26: ...26 Chapter 2 Overview NN40010 300 ...
Страница 72: ...72 Chapter 6 R2MFC MBM maintenance NN40010 300 ...
Страница 90: ...90 Chapter 7 Command Line Interface CLI NN40010 300 ...
Страница 108: ...108 Configuring DIP switch settings and definitions NN40010 300 ...
Страница 110: ...110 Diagnostic and loopback DIP switch settings NN40010 300 ...
Страница 112: ...112 MFC Signal Definitions NN40010 300 ...
Страница 114: ...114 CLI Cable Pinout NN40010 300 ...