Chapter 4 Installing the R2MFC MBM
35
R2MFC Media Bay Module Installation and Configuration Guide
Installing an R2MFC MBM in the expansion unit
Perform the following steps to install an R2MFC MBM in the BCM expansion unit chassis. Install
the R2MFC MBM when the system is powered down:
1
Ensure that both the faceplate and underside DIP switches on the R2MFC MBM are set
correctly. For information on how to set the faceplate switches, refer to
“Setting Config DIP
switches” on page 49
. For information about how to set the underside switches, refer to the
BCM Installation and Maintenance guide for the host system.
2
Remove the front bezel from the expansion unit.
3
Select an open media bay.
4
With the faceplate of the R2MFC MBM facing toward you, insert the R2MFC MBM into the
open bay. Ensure that any cables at the rear of the module are clear of the platform base
chassis.
5
Push the R2MFC MBM into the unit. You will hear a click when the module is firmly seated in
the media bay.
6
Install the front bezel on the expansion unit.
Caution:
Only install the R2MFC MBM when the system is powered down. See
“Shutting down the system” on page 32
.
Warning:
Failure to follow procedures to properly disconnect the BCM and
expansion unit can result in module or system damage.
Содержание R2MFC
Страница 12: ...12 NN40010 300 ...
Страница 14: ...14 How to Get Help NN40010 300 ...
Страница 20: ...20 Chapter 1 Getting started NN40010 300 NN40010 300 ...
Страница 26: ...26 Chapter 2 Overview NN40010 300 ...
Страница 72: ...72 Chapter 6 R2MFC MBM maintenance NN40010 300 ...
Страница 90: ...90 Chapter 7 Command Line Interface CLI NN40010 300 ...
Страница 108: ...108 Configuring DIP switch settings and definitions NN40010 300 ...
Страница 110: ...110 Diagnostic and loopback DIP switch settings NN40010 300 ...
Страница 112: ...112 MFC Signal Definitions NN40010 300 ...
Страница 114: ...114 CLI Cable Pinout NN40010 300 ...