66
Chapter 6 R2MFC MBM maintenance
NN40010-300
Table 13
shows the reactions for Group II alarms when they persist.
Faceplate LEDs
There are two sets of LEDs on the faceplate of the R2MFC MBM. The system status LEDs are
made up of the Power LED, In Service LED, and Diag LED.
Table 14
shows the LEDs and their
states.
•
As the BCM starts, the In Service LED is Green Flashing.
•
Once powered up, the Power LED is set to Green, the In Service LED is set to green, and the
Diag LED is off.
•
When the MBM is operating properly, the In Service LED is Green Solid.
•
During an alarm on the internal PRI link, the In Service LED is off.
•
During test mode, the Diag LED is red.
CRC-4 errors
RAI
AIS
FEBE
none
none
Table 13
Group II alarms propagation
Error Condition
Alarm Transmitted to far-end
Alarm sent on opposite link
LOS
RAI
AIS
AIS
RAI
AIS
OOF
RAI
AIS
OOM
TS16
RAI
TS16
AIS
AIS
TS16
RAI
TS16
AIS
RAI
None
RAI
RAI
TS16
None
RAI
TS16
DCH down
None
AIS
Table 14
System status monitor LEDs
LED Status
LED Name
Green Solid
Green Flashing
Red Solid
Red Flashing
OFF
Power
Active Power
N/A
N/A
N/A
No Power
In-Service
Normal Operation Start Up
N/A
N/A
Out-of-Service
Diag
N/A
N/A
Test Mode
N/A
Normal Operation
Table 12
Group I Alarms propagation (Sheet 2 of 2)
Error Condition
Alarm Transmitted to far end
Alarm sent on opposite link
Содержание R2MFC
Страница 12: ...12 NN40010 300 ...
Страница 14: ...14 How to Get Help NN40010 300 ...
Страница 20: ...20 Chapter 1 Getting started NN40010 300 NN40010 300 ...
Страница 26: ...26 Chapter 2 Overview NN40010 300 ...
Страница 72: ...72 Chapter 6 R2MFC MBM maintenance NN40010 300 ...
Страница 90: ...90 Chapter 7 Command Line Interface CLI NN40010 300 ...
Страница 108: ...108 Configuring DIP switch settings and definitions NN40010 300 ...
Страница 110: ...110 Diagnostic and loopback DIP switch settings NN40010 300 ...
Страница 112: ...112 MFC Signal Definitions NN40010 300 ...
Страница 114: ...114 CLI Cable Pinout NN40010 300 ...