Chapter 5 Configuring the R2MFC MBM
53
R2MFC Media Bay Module Installation and Configuration Guide
3
Select the appropriate
Bus #
under
Configuration > Resources > Telephony Resources
in
the navigation tree.
The Bus # information frame displays. See
Figure 19
for an example of the screen layout for
an R2MFC MBM configured on Bus 2.0.
Figure 19
BCM Bus configuration for R2MFC MBM
4
Configure the fields in the
Details for Module: 2.0
panel. See
Table 7
for parameters and
settings.
Table 7
Module configuration parameters
Parameter
Setting
Trunk type
PRI
Protocol
Euro
Clock source
Primary external (if only one
trunk module in system;
otherwise, it depends on the
synchronization scheme of
the BCM)
Overlap receiving
Selected (On)
Local number length
According to BCM local
dialing plan (customer -
dependent)
Note:
This field appears
only when the Overlap
receiving field is selected.
E1 Parameters - CRC4
Not Selected (Off)
Содержание R2MFC
Страница 12: ...12 NN40010 300 ...
Страница 14: ...14 How to Get Help NN40010 300 ...
Страница 20: ...20 Chapter 1 Getting started NN40010 300 NN40010 300 ...
Страница 26: ...26 Chapter 2 Overview NN40010 300 ...
Страница 72: ...72 Chapter 6 R2MFC MBM maintenance NN40010 300 ...
Страница 90: ...90 Chapter 7 Command Line Interface CLI NN40010 300 ...
Страница 108: ...108 Configuring DIP switch settings and definitions NN40010 300 ...
Страница 110: ...110 Diagnostic and loopback DIP switch settings NN40010 300 ...
Страница 112: ...112 MFC Signal Definitions NN40010 300 ...
Страница 114: ...114 CLI Cable Pinout NN40010 300 ...