Data administration
Page 45 of 66
DTI/CPI
Installation and data administration
LFAC
0-(3)-128
24-hour loss of frame alignment threshold.
If 0 is entered, trunks will be restored to service automatically.
BIPV
1-(3)-4,
1-(2)-4
Bit error rate (bipolar violation and CRC) monitoring limits.
Maintenance threshold.
Out-of-service threshold.
SRTK
1-(5)-24,
1-(30)-3600
Frame slip/tracking/monitoring limits.
Maintenance threshold, the minimum time, in hours, between slips.
Out-of-service threshold, the maximum number of slips per hour.
SRNT
1-(15)-1024,
1-(3)-1024
Frame slip/free run (non-tracking)/monitoring limits
Maintenance threshold, the minimum time, in seconds, between
10 consecutive slips. When the threshold is reached, warnings are
output to the maintenance TTY.
Out-of-service threshold, the minimum time, in seconds, between
10 consecutive slips. When the threshold is reached, the DTI loop
is taken out of service and a minor alarm is raised.
Note:
Automatic restoration is available only with Release 12 and later software.See
Digital Trunk
Interface/Computer-to-PBX Interface maintenance
(553-2811-500) for a description.
SRIM
1-127
Improvement timer in minutes.
SRMM
1-(2)-127
Improvement criteria. If non-tracking mode maintenance threshold
is exceeded SRMM or fewer times in duration of SRIM, trunks are
returned to service. If not, timer is restarted and monitoring
continues.
LFAL
1-(17)-10240
1-(511)-1024
0
Loss of frame alignment monitoring limits.
Maintenance threshold.
Out-of-service threshold, the number of frame losses in 24 hours.
Step 2
Gather data to add, modify, or remove a digital trunk loop. The following prompts in
LD 17
require a response. Defaults are in parentheses.
REQ
ADD, CHG,
OUT
Action Request (add, change, or remove data).
TYPE
CFN
Configuration data block.
CEQU
Yes, (No)
Change CE parameters.
DLOP
lll dd ff
Digital Trunk loop options.
lll = network loop number 0-159.
dd = number of data calls 0-(24).
ff = frame format D2, D3, D4, or ESF.
The default for frame format (ff) is ESF if prompt MODE is set to
PRI; D3 if MODE is set to DTI or LINK.
Prompt
Response
Comments