DTI installation
Page 15 of 66
DTI/CPI
Installation and data administration
Removing the DTI card
1
Disable Network Loop using DTI Maintenance LD 60. The command is
DISL loop.
2
Remove data from memory.
3
Determine the cabinet and shelf location of the cards to be removed.
4
Remove cross connections at MDF to wall-mounted cross-connect
terminal.
5
Disconnect DTI cables at Echo Canceller and at carrier interface (for
example, Office Repeater, NCTE equipment).
6
Tag and disconnect cables from card. Rearrange Clock Controller card
cables if required.
7
Remove DTI and Network cards.
Note:
In a dual system, if the other circuit of the dual Network card is in
use, ignore Step 7 for the Network card.
8
Pack and store card.
9
Close cabinet doors.
ST, STE systems
For basic information on installing a DTI card, refer to
for DTI cabling arrangement in these
systems.