Page 44 of 188
PRI installation: NT, 51/51C, 61/61C
553-2901-200 Standard 11.00 August 1996
Installing the QPC720 PRI
This procedure describes how to install the QPC720 PRI card in an NT,
51/51C, or 61/61C.
Procedure 6
Installing the QPC720 PRI in NT, 51/51C, 61/61C
1
Determine the cabinet and shelf location of the circuit card to be
installed. The following slots can be used if they are not required for
other cards.
Table 11
Shelf and slot location of QPC720 in NT or option 61
System
Shelf
Slot
NT
QSD39 Network (LH)
QSD40 Network (RH)
QSD39 DTI/PRI only
QSD40 DTI/PRI only
5–10 Note 1
5–10 Notes 1, 2
2–10 Notes 1, 4
12–14
2–3 Note 1
5–13
61/61C
NT6D39 CPU/NET
NT8D35 DTI Exp Cube
NT8D47 RPE Cube
3–8 Note 1
18 Note 3
2–3 Note 1
5–14 Note 1
1, 11, 12
Note 1:
DTI/PRI packs require two slots. The slot indicated is the maximum slot
that the pack resides in. For example, the slot 14 pack uses slots 13 and 14.
Note 2:
The DTI/PRI pack cannot be installed in slot 11. The pack would come in
contact with the BTU installed between slots 11 and 12.
Note 3:
Slot 18 is only available on CPU shelf, which has no MDU/FDU.
Note 4:
DTI/PRI pack could reside in slots 10 and 11, but cannot reside in slots 11
and 12 because of powering restrictions.