NTD12 Dual-port DTI/PRI card description and installation Page 149 of 188
ISDN PRI Installation
Configuring the NT5D12 DDP
After the NT5D12 DDP has been installed, it may be configured using the
same procedures as for the standard QPC720 PRI card. Refer to the ISDN PRI
Description and Administration (553-2901-100) document.
Consider the following when configuring the NT5D12 DDP card:
— The Meridian 1 software allows four ports to be defined for the NT6D80
MSDL. The DDCH (NTBK51AA) card has only two ports, 0 and 1;
therefore, ports 2 and 3 must not be defined when using the NTBK51AA;
— Port 0 of the NTBK51AA can only be defined to work with Loop 0 of the
NT5D12 DDP card, and Port 1 of the NTBK51AA can only be defined
to work with Loop 1 of the NT5D12. This relationship must be reflected
when configuring a new DCH in overlay 17 (in response to the DCHL
prompt, enter either 0 or 1 when specifying the loop number used by the
DCH);
— You cannot define one of the DDP loops for the NTBK51AA DDCH,
and the other loop for for the QPC757 DCHI or the NT6D80 MSDL.