![Nortel NT5D12 Скачать руководство пользователя страница 184](http://html1.mh-extra.com/html/nortel/nt5d12/nt5d12_installation-manual_1706448184.webp)
Page 179 of 188
ISDN PRI Installation
180
ISDN card slot positions
The following tables illustrate acceptable positions for the QPC720, QPC414,
QPC471, QPC775, QPC757, and NT6D80 cards.
Use this chart to determine where you are placing your cards before you
actually begin your installation.
Table 49
Card slot positions for 21/ 21E, 51/51C, 61/61C, 71, and 81/81C
21
21E
51/51C,
61/61C
71
81/81C
QPC414
1 slot
CE/PE:
4–9 (Net)
CE/PE:
4–9 (Net)
CPU/Net:
1–8
Net: 5–12
Net: 5–12
QPC720
2 slots
CE/PE:
4–8 (Net)
RPE:
1, 11–12
CE/PE:
4–8 (Net)
RPE:
1, 11–12
CPU/Net: 3–8
RPE:
1, 11–12
CPU:
8–13, 15–16
Net: 5–10,
13–14
RPE: 1, 11–12
Core: 0–3
Net: 5–10,
13–14
RPE: 1, 11–12
QPC471
QPC775
1 slot
per CPU
CE/PE:
4–7 (Net)
CE/PE:
4–7 (Net)
CPU/Net: 9
CPU: 14
COR/Net: 9
QPC757
1 slot
CE/PE:
4–9 (Net)
CE/PE:
4–9 (Net)
CPU/Net:
1–8, 13
CE/Net: 5–14
CE/Net: 5–14
NT6D80
1 slot
—
CE/PE:
4–9 (Net)
CPU/Net:
1–8, 13
CE/Net: 5–14
CE/Net: 5–14
COR/Net: 0-8