128 Environmental, power, and safety considerations
555-4001-136 Standard 05.06 May 2002
Power consumption
Table 31 shows the power consumption for the M3900 series sets.
Line engineering
M3900 Series Meridian Digital Telephones use twisted pair wiring on
transmission lines. The maximum acceptable loop length is 1067 m.
(3500 ft.), assuming 24 AWG (0.5 mm) standard twisted wire with no
bridge taps. A 15.5 vdB loss at 256 kHz defines the loop length limit.
Longer lengths are possible, depending on the wire’s gauge and
insulation.
Table 31
M3900 sets power consumption
M3901
M3902
M3903
M3904
M3905
Idle
29.3
37.3
42.5
31.5
15.02
H/F Nominal
45.7
48.7
37.5
H/F Maximum
64.3
59.7
46.4
DBA Idle
39.29
15.31
DBA H/F Nominal
45.9
DBA H/F
Maximum
52
2 KBA Idle
33.42
14.98
Note: Units of measurement are milli-amps (ma).
The M3905 uses a switch mode power supply and the M3904 uses a linear power supply.
When a handset is offhook with maximum volume, the current increases 2 to 5 ma using linear power
supply and 1.5 ma on the M3905 using switch mode power supply.
WARNING
Use only the line cord provided with the telephone. A line cord
designed for another telephone can cause damage to the
equipment.
Warning
Содержание Meridian M3900
Страница 2: ......
Страница 4: ......
Страница 6: ...vi Publication history 555 4001 136 Standard 05 06 May 2002...
Страница 26: ...26 Feature keys 555 4001 136 Standard 05 06 May 2002...
Страница 32: ...32 Feature codes and abbreviations 555 4001 136 Standard 05 06 May 2002...
Страница 42: ...42 M3902 telephone set 555 4001 136 Standard 05 06 May 2002...
Страница 56: ...56 M3904 professional telephone 555 4001 136 Standard 05 06 May 2002...
Страница 64: ...64 M3905 ACD telephone 555 4001 136 Standard 05 06 May 2002...
Страница 139: ......