Installing ISDN BRI hardware
Page 19 of 120
Installation and Configuration
Table 2 lists the modules that can house ISDN BRI cards.
Table 2
ISDN BRI card location
2
Locate the card slots in the modules that house ISDN BRI cards. Group
all SILCs, UILCs, BRSCs, superloops and the MISP that supports them in
the same network group to avoid using junctors for dedicated
connections.
End of Procedure
The following rules apply when selecting the card slots:
MISPs
•
MISPs are inserted into the Core/Network Module for Large Systems
(Multi Group). Refer to the LD 22 printout to identify modules with
unused network card slots and to Table 2 for the card slots in these
modules that can house MISPs.
•
An MISP cannot share network loop addresses with a Superloop
Network Card in the Large Systems. The MISP requires two network
loop addresses and one network card slot.
•
An MISP supports a maximum of 8 BRSCs and two line cards.
Modules
Supported
Systems
SILCs,
UILCs,
BRSCs
MISPs
NT4N41
Core/Network Module
Large
Systems
—
Network
slots
0-7
NT8D35
Network Module
81C CPPII
—
Network
slots
5-12
NT8D37
IPE Module
All systems
IPE slots
0-15
—
Содержание Communication Server 1000M
Страница 2: ......
Страница 4: ...Page 4 of 120 Revision history 553 3001 218 Standard 2 00 September 2004...
Страница 12: ...Page 12 of 120 About this document 553 3001 218 Standard 2 00 September 2004...
Страница 16: ...Page 16 of 120 Preparing for installation 553 3001 218 Standard 2 00 September 2004...
Страница 52: ...Page 52 of 120 Installing ISDN BRI hardware 553 3001 218 Standard 2 00 September 2004...
Страница 90: ...Page 90 of 120 Configuring ISDN BRI hardware 553 3001 218 Standard 2 00 September 2004...
Страница 98: ...Page 98 of 120 Preparing the system 553 3001 218 Standard 2 00 September 2004...
Страница 120: ...Page 120 of 120 Generating traffic reports 553 3001 218 Standard 2 00 September 2004...
Страница 121: ......