![Nortel CallPilot 702t Скачать руководство пользователя страница 191](http://html.mh-extra.com/html/nortel/callpilot-702t/callpilot-702t_installation-and-configuration-manual_1707006191.webp)
October 2002
Performing RAID maintenance
Part 5: 702t Server Maintenance and Diagnostics
191
5
Select Physical Device, and then press Enter.
Result:
The Physical Drive Selection window appears. All hard drives
are offline.
6
In the Physical Drive Selection window, select the fourth hard drive, and
then press Enter.
Result:
The device pop-up menu appears.
7
Select Advanced Options, and then press Enter.
Result:
The advanced options pop-up menu appears.
8
Select Make Drive Online, and then press Enter.
Result:
A message appears warning that making a drive online may
cause data corruption. For this procedure, disregard this message.
9
Select Yes, and then press Enter.
Result:
The system prompts you to confirm.
10
Select Yes, and then press Enter.
Result:
You return to the Physical Drive Selection window. The hard
drive that was selected is now set to Online.
.
CAUTION
Risk of lost or corrupted data
All hard drives must be offline before you continue with the rest
of this procedure.
.
CAUTION
Risk of data corruption
Ensure that you select a pre-upgrade drive for this step. If this
is a standard configuration and you have followed the
instructions in this procedure, the fourth, fifth, and sixth hard
drives are the pre-upgrade drives. If this is not correct for your
system, contact Nortel Networks technical support.
Содержание CallPilot 702t
Страница 2: ...P0949453 ...
Страница 6: ...vi CallPilot Publication history Standard 1 0 ...
Страница 26: ...Troubleshooting your CallPilot system Standard 1 0 26 CallPilot ...
Страница 50: ...Using Windows NT online diagnostic tools Standard 1 0 50 CallPilot ...
Страница 62: ...Using serial port diagnostic tools Standard 1 0 62 CallPilot ...
Страница 76: ...Using CallPilot Manager to monitor hardware Standard 1 0 76 CallPilot ...
Страница 102: ...Using CallPilot Manager to monitor hardware Standard 1 0 102 CallPilot ...
Страница 194: ...Performing RAID maintenance Standard 1 0 194 CallPilot ...
Страница 240: ...Performing RAID maintenance Standard 1 0 240 CallPilot ...
Страница 254: ...Replacing or adding voice processing boards Standard 1 0 254 CallPilot ...
Страница 264: ...Replacing DIMMs and the CPU Standard 1 0 264 CallPilot ...
Страница 284: ...SSU and BIOS Standard 1 0 284 CallPilot ...
Страница 304: ...Index Standard 1 0 304 CallPilot ...
Страница 305: ......