Chapter 10 Troubleshooting
65
CallPilot Mini/CallPilot 150 Installation and Maintenance Guide
•
power supply cord is connected to the CallPilot Mini/CallPilot 150 module
•
CallPilot Mini/CallPilot 150 module is getting power from the AC socket
4
Unplug the module and open the front cover. Remove the feature cartridge and then re-insert
it. Make sure the feature cartridge is fully inserted in the slot.
5
Close the front cover and plug in the module.
The Power-on Diagnostics fail
When LEDs
1 and
2 blink quickly, it indicates a Power-on Diagnostics fail. For information
about other LED error codes, refer to
“CallPilot Mini/CallPilot 150 LEDs” on page 27
.
One of the following two components could be the cause of the problem: the power supply or the
CallPilot Mini/CallPilot 150. To correct the problem:
1
Measure the power supply voltage. If the voltage is out of specifications, replace the power
supply and retest the system.
The power supply provides 9 VDC.
2
If the power supply is within specifications, replace the CallPilot Mini/CallPilot 150, then
reprogram and test the system.
Cannot access CallPilot Manager
If you cannot access CallPilot Manager, do the following:
1
Wait until LED
turns on before attempting to access CallPilot Manager. If LED
does not turn on, refer to
“LED 6 does not turn on after CallPilot Mini/CallPilot 150 has
finished starting up” on page 69
.
2
Make sure that the IP address, subnet mask and default gateway settings are correct.
3
Make sure another device is not using the CallPilot Mini/CallPilot 150 IP address. To test this,
disconnect the CallPilot Mini/CallPilot 150 from the network and use a computer on the
network to ping the CallPilot Mini/CallPilot 150 IP address. If another device answers the
ping, the CallPilot Mini/CallPilot 150 IP address is being used by another device.
CallPilot Mini/CallPilot 150 fails during a start up
If the CallPilot Mini/CallPilot 150 fails during a start up, do the following:
1
Remove power from the CallPilot Mini/CallPilot 150.
2
Check that the Software Cartridge is properly seated in the Compact Flash Adapter.
3
Check that the Compact Flash Adapter is properly seated in the CallPilot Mini/CallPilot 150.
4
Restore power to the CallPilot Mini/CallPilot 150.
Содержание CallPilot 150
Страница 1: ...Part No P0990474 03 CallPilot Mini CallPilot 150 Installation and Maintenance Guide...
Страница 8: ...8 P0990474 03...
Страница 10: ...10 P0990474 03...
Страница 28: ...28 Chapter 4 Installing CallPilot Mini CallPilot 150 P0990474 03...
Страница 46: ...46 Chapter 5 Initializing the CallPilot Mini CallPilot 150 P0990474 03...
Страница 58: ...58 Chapter 8 Backing up and restoring CallPilot P0990474 03...
Страница 62: ...62 Chapter 9 Upgrading CallPilot Mini CallPilot 150 P0990474 03...
Страница 70: ...70 Chapter 10 Troubleshooting P0990474 03...
Страница 90: ...90 Glossary P0990474 03...
Страница 94: ...94 Index P0990474 03...