Chapter 3 Using the console interface
201
Using the Business Policy Switch 2000 Version 2.0
Range
None, IP Ether2, Ipx 802.3, Ipx 802.2, Ipx Snap, Ipx Ether2, AplTk
Ether2Snap, Declat Ether2, DecOth Ether2, Sna 802.2, Sna
Ether2, NetBios 802.2, Xns Ether2,Vines Ether2, Ipv6 Ether2,
User-Defined, Rarp Ether2
User-Defined PID
Allows you to create your own user-defined VLAN where you specify the Protocol
Identifier (PID) for the VLAN. To set this field, the VLAN State field must be set to
Inactive. Some restrictions apply.
“User-Defined Protocol Identifier Description” on
Default
0x0000
Range
Any 16-bit hexadecimal value (for example, 0xABCD)
VLAN State
Allows you to activate your newly created VLAN.
The following field values: VLAN Type, Protocol Id (PID), or User-defined PID must
be configured appropriately before this field can be set to active. After you set the
VLAN State field value to Active, you cannot change the VLAN State, VLAN Type,
Protocol Id, or User-defined PID field values, unless you delete the VLAN.
If you delete a VLAN, all configuration parameters that are associated with that
VLAN are also deleted.
Default
Inactive
Range
Inactive, Active
Port Membership
Allows you to assign VLAN port memberships to
standalone
or
stacked unit
ports.
The ports can be configured in one or more VLANs. To set this field, you must set
the VLAN State field to Active. Certain restrictions apply for the BayStack
450-1GBIC, 450-SR, 450-1SX, 450-1LR, 450-1LX MDA sand BayStack 410 ports
(see
“Port restrictions” on page 205
This field is dependent on the Tagging field value in the VLAN Port Configuration
screen (see the Tagging field description in
“VLAN Port Configuration screen fields”
For example:
•
When the Tagging
field is set to
Untagged Access
, you can set the Port
Membership field as an untagged port member (U) or as a non-VLAN port
member (-).
•
When the Tagging
field is set to
Tagged Trunk
, you can set the Port Membership
field as a tagged port member (T) or as a non-VLAN port
member (-).
The Port Membership fields are displayed in six-port groups (for example, 1-6, 7-12,
13-18). The number of ports displayed depends on the switch model or type of
optional MDA installed in the Uplink Module slot.
Default
U (All ports are assigned as untagged members of VLAN 1.)
Range
U, T, and -
Table 23
VLAN Configuration screen fields (continued)
Field
Description
Содержание business policy switch 2000
Страница 16: ...16 Contents 208700 C ...
Страница 22: ...22 Figures 208700 C ...
Страница 26: ...26 Tables 208700 C ...
Страница 32: ...32 Preface 208700 C ...
Страница 308: ...308 Chapter 4 Policy enabled networks 208700 C ...
Страница 348: ...348 Chapter 5 Sample QoS configuration 208700 C ...
Страница 392: ...392 Appendix D Connectors and pin assignments 208700 C ...