55
Installation
ADSL WAN module replacement
The following sections describe how to replace the ADSL WAN module in a Business Services
Gateway 12-port (BSG12aw).
ADSL WAN module replacement navigation
•
“Saving the running configuration to Flash using the WebUI” on page 55
•
“Saving the running configuration to Flash using the CLI” on page 56
•
“Replacing the ADSL WAN module” on page 56
•
“Verifying the ADSL WAN module status” on page 57
Prerequisites to ADSL WAN module replacement
•
If the system is still operating, perform the procedure
“Shutting down the BSG8ew/12ew/
aw/tw” on page 63
.
•
Obtain an ADSL WAN Replacement Module (NT5S21ZCE6) for the BSG12aw from
Nortel.
•
Ensure you have the following items available:
— an antistatic wrist grounding strap
— a Phillips screwdriver
— grounding source
Saving the running configuration to Flash using the WebUI
Use this procedure to save the running configuration using the WebUI.
Procedure steps
Step
Action
1
From the BSG12aw logon page, log on using the user ID and password.
2
From the left-hand navigation panel, select
Administration
,
Configuration
File
,
Save
.
3
Click
Apply
.
End
Caution:
Risk of equipment damage
You must wear an antistatic grounding strap at all times when handling
electronic components. Failure to do so can result in damage to the equipment.
Содержание BSG12aw
Страница 10: ...10 New in this release NN47928 302 NN47928 302 ...
Страница 24: ...24 Hardware overview NN47928 302 NN47928 302 ...
Страница 44: ...44 Installation options NN47928 302 NN47928 302 ...
Страница 50: ...50 Cable connection NN47928 302 NN47928 302 ...
Страница 52: ...52 System verification NN47928 302 NN47928 302 ...
Страница 66: ...66 Basic procedures NN47928 302 NN47928 302 ...