Downgrade a full system
119
Downgrading a non-redundant system navigation
•
"Downgrading a non-redundant system with a replicated database"
(page 119)
•
"Downgrading a non-redundant system with a single database" (page
119)
Prerequisites
•
For information about downgrading a database, see
"Downgrading a
database" (page 114)
.
•
For information about downgrading AudioCodes, see
"Downgrading the
AudioCodes gateway" (page 113)
.
•
For information about downgrading Network Elements, see
"Downgrading the Network Elements" (page 113)
.
•
For information about downgrading the System Manager, see
"Downgrading the System Manager" (page 113)
.
Downgrading a non-redundant system with a replicated
database
Procedure Steps
Step
Action
1
Downgrade the secondary database.
2
Downgrade the AudioCodes Gateway.
3
Downgrade the Network Elements.
4
Downgrade the System Manager.
5
Re-synchronize the databases.
--End--
Downgrading a non-redundant system with a single database
Procedure Steps
Step
Action
1
From the System Management console, stop all active Network
Elements in the following order:
•
Provisioning Managers
•
Personal Agent Managers
•
Session Managers
•
Accounting Managers
Application Server 5300
Nortel AS 5300 Installation
NN42040-300
01.04
4 November 2008
Copyright © 2007-2008 Nortel Networks
.
Содержание Application Server 5300
Страница 123: ......