Installing the firmware upgrades
107
Procedure Steps
Step
Action
1
Load the hard drive firmware upgrade CD into the CD-ROM
drive.
2
Log on to the server as the SSA role (ntsysadm).
3
Reboot the server.
sudo reboot
4
If the operating system has been installed, change the boot
sequence so that the CD-ROM is the primary boot device by
doing the following:
•
When the BIOS information appears, press F12 to select the
boot sequence.
•
Select CD-ROM as the primary boot device.
Otherwise, wait for the server to reboot.
The ServeRAID Manager Hard Drive Update screen appears.
5
If an upgrade is required, press Enter to apply the upgrade.
The hard drive firmware upgrade is installed.
Otherwise, press Enter and go to step 7.
6
Select OK twice to complete the upgrade.
Attention:
Do not power off the system during the upgrade.
7
When the update completes, remove the CD from the CD-ROM
drive and select OK to boot the operating system.
--End--
Installing ServeRAID firmware upgrades
Use this procedure to install ServeRAID firmware upgrades. This
procedure requires the reboot of the server.
Prerequisites
•
You must be assigned to the SSA role (ntsysadm).
•
You must have the CD containing the ServeRAID firmware upgrade
file.
Application Server 5300
Nortel AS 5300 Installation
NN42040-300
01.04
4 November 2008
Copyright © 2007-2008 Nortel Networks
.
Содержание Application Server 5300
Страница 123: ......