100
Maintenance Releases
Querying the Network Interface Card firmware
Use this procedure to determine the current Network Interface Card (NIC)
firmware version.
Prerequisites
•
You must be assigned to the SSA role (ntsysadm)
Procedure Steps
Step
Action
1
Log on to the system as the SSA role (ntsysadm).
2
Run the following command:
sudo ethtool –i <ethernet_device>
The system displays the device properties, including the
currently installed firmware version.
firmware-version:
x.x.x
--End--
Variable definitions
Variable
Value
ethernet_device
eth0 or eth1
Querying the hard drive firmware
Use this procedure to determine the current hard drive firmware version.
Prerequisites
•
You must be assigned to the SSA role (ntsysadm)
Procedure Steps
Step
Action
1
Log on to the server as the SSA role (ntsysadm).
2
Run the following command:
arcconf GETCONFIG 1 pd
The system displays the physical device information for each
installed hard drive. The firmware version is included in the list
of information for each device.
Firmware :
xxxx
--End--