Page 46 of 66 Card Specific Loadware Upgrades
NTPH13AA_maint 3.01 February 2006
After a failed upgrade, the following messages are printed:
DSP Code checksum failed
Checksum = 0xf8f9c9b6
DSP Load upgrade Failed!!!!!
0x36b254 (tUpgradeDsp): On-board DSP section in reset.
0x36b254 (tUpgradeDsp): Powering up dsp 0
The Agent Greeting Card must be in maintenance mode before an
upgradeDsp can be executed. Maintenance mode is entered by disabling the
card via Overlay 32 on the Meridian switch. Once upgrade is complete the
card can be re-enabled via Overlay 32.
!
CAUTION!
This Procedure can not be performed on the Media Card
(NTVQ09BA) platform.
Содержание Agent Greeting NTVQ09AB