Chapter 2 Cabling the gateway and turning the power on
39
Installing the Contivity 1700
T1/E1 CSU/DSU WAN interface card LEDs
Figure 13
shows the LEDs on the T1/E1 CSU/DSU WAN interface card.
Figure 13
LEDs on the T1/E1 CSU/DSU WAN interface card
Table 9
describes the LEDs on the T1/E1 CSU/DSU WAN interface card.
Table 9
LED indicators on the T1/E1 CSU/DSU WAN interface card
LED
Indicator
Description
LED 1
Red
Red alarm LED is lit when a loss-of-signal (LOS) or
out-of-frame (OOF) condition is detected on the receive
signal.
LED 2
Blue
Blue alarm LED is lit when receiving an upstream failure
denoted by an alarm indication signal (AIS).
LED 3
Yellow
Yellow alarm LED is lit when the far-end equipment is in
the red alarm condition.
LED 4
Green
Normal operation.
CS160012A
LED 4, Green
LED 3, Yellow
LED 1, Red
LED 2, Blue