background image

Technical Specifications

204515-C

A-3

 

Passport 8190SM Switch Management Module

Electromagnetic Emissions

Meets requirements of:

US: FCC CFR 47, Part 15, Subpart B, Class A

Canada: ICES-003, Issue-2, Class A

Australia/New Zealand: AS/NZS 3548:1995, Class A

Japan: VCCI V-3/97.04, Class A

Taiwan: CNS 13438, Class A

EN 55 022 (CISPR 22:1985), Class A 

CE Mark

Electromagnetic Immunity:

EN50082-1:1997

Physical Specifications

Height:

1.5 in. (3.8 cm)

Width:

15.4 in. (39.1 cm)

Depth:

18.5 in. (47.0 cm)

Weight:

7 lb (3.15 kg)

Electrical Specifications

Input Current:

75 W

Thermal Rating:

250 BTU/hr maximum

MTBF Rating

229,623 hr

Connector Types

Ethernet Management port: 

RJ-45 connector wired as MDI-X (

Table A-1

)

Console port:

DB-9 connector (

Table A-2

)

Modem port:

DB-9 connector (

Table A-3

)

Required Cables

Ethernet Management port:

Category 3, 4, or 5 UTP cable (10 Mb/s operation)
Category 5 UTP cable (100 Mb/s operation)

Console port:

RS-232 cable

Modem port:

DTE-to-DCE cable (straight or transmit cable)

Содержание 1000BASE-XD

Страница 1: ...Part No 204515 C April 2000 4401 Great America Parkway Santa Clara CA 95054 Using the Passport 8100 Modules ...

Страница 2: ...onment This equipment generates uses and can radiate radio frequency energy If it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to take whatever measures may be necessary to correct the interfe...

Страница 3: ...YOU ACCEPT ALL OF THE TERMS AND CONDITIONS OF THIS LICENSE AGREEMENT THE TERMS EXPRESSED IN THIS AGREEMENT ARE THE ONLY TERMS UNDER WHICH NORTEL NETWORKS WILL PERMIT YOU TO USE THE SOFTWARE If you do not accept these terms and conditions return the product unused and in the original shipping container within 30 days of purchase to obtain a credit for the full purchase price 1 License Grant Nortel ...

Страница 4: ...tel Networks does not warrant a that the functions contained in the software will meet the Licensee s requirements b that the Software will operate in the hardware or software combinations that the Licensee may select c that the operation of the Software will be uninterrupted or error free or d that all defects in the operation of the Software will be corrected Nortel Networks is not obligated to ...

Страница 5: ...at it will not without first obtaining all export licenses and approvals required by the U S Government i export re export transfer or divert any such Software or technical data or any direct product thereof to any country to which such exports or re exports are restricted or embargoed under United States export control laws and regulations or to any national or resident of such restricted or emba...

Страница 6: ...vi 204515 C ...

Страница 7: ...DCE Switch 1 6 Serial Ports 1 6 Reset Button 1 6 PCMCIA Card Slot 1 6 LEDs 1 7 Passport 8132TX 32 Port I O Module 1 8 10BASE T 100BASE TX Port Connectors 1 8 MDA Slot 1 9 Comm Port 1 9 LEDs 1 10 Passport 8148TX 48 Port I O Module 1 11 LEDs 1 12 Passport 8108GBIC 8 Port I O Module 1 12 LEDs 1 13 Redundancy Features 1 13 Redundant Passport 8190SM Modules 1 14 Redundant Power Supplies 1 14 Combining ...

Страница 8: ...he Switch 3 3 Logging On to the System 3 4 Assigning an IP Address to the Management Port 3 5 Setting System Identification 3 5 Setting System Security 3 6 Switch Configuration 3 8 Chapter 4 Troubleshooting Normal Power Up Sequence 4 1 Failure to Get a Login Prompt from the Console Port 4 2 Failure of Management Software to Recognize I O Modules 4 2 LED Indications of Problems 4 2 Port Connection ...

Страница 9: ...ort Connectors A 6 Comm Port Connector A 7 MDAs A 7 Passport 8148TX Module A 8 Port Connectors A 8 Passport 8108GBIC Module A 9 GBICs A 9 1000BASE SX GBIC A 10 1000BASE LX GBIC A 10 1000BASE XD GBIC A 11 1000BASE ZX GBIC A 11 MDI and MDI X Connections A 12 Declaration of Conformity A 13 Appendix B LEDs Passport 8190SM Switch Management Module B 1 Passport 8132TX and 8148TX I O Modules B 3 Passport...

Страница 10: ... C Appendix C Media Dependent Adapters 450 Series MDAs C 2 8100 4TX MDA C 4 8100 Series Fiber MDAs C 5 Installing an MDA C 7 Appendix D Installing GBICs Installing a GBIC D 2 Appendix E RFCs and Standards Index ...

Страница 11: ... Removing a Filler Panel 2 3 Figure 2 2 Inserter Extractor Levers in Extended Position 2 3 Figure 2 3 Inserting a Module 2 4 Figure 2 4 Seating the Backplane Connectors 2 4 Figure 2 5 Securing the Module in the Chassis 2 5 Figure 2 6 Routing Network Cables 2 7 Figure 3 1 Port Numbers on High Density Modules 3 2 Figure 4 1 DCE DTE Switch on the Passport 8190SM Module 4 2 Figure A 1 MDI X to MDI Cab...

Страница 12: ... 2 Figure C 2 1000BASE LX Longwave Gigabit MDA Front Panels C 3 Figure C 3 8100 4TX MDA Front Panel C 4 Figure C 4 8100 Series MDA Front Panels C 6 Figure C 5 Installing an MDA C 7 Figure D 1 Types of GBICs D 1 Figure D 2 Installing a GBIC D 2 Figure D 3 Removing a GBIC D 3 ...

Страница 13: ... 5 Table A 3 DTE to DCE Pin Assignments A 5 Table A 4 Passport 8132TX Port Pinouts A 6 Table A 5 Passport 8148TX Port Pinouts A 8 Table B 1 LED Operation on the Passport 8190SM Module B 2 Table B 2 Module LEDs on the Passport 8132TX and 8148TX Modules B 4 Table B 3 Port LEDs on the Passport 8132TX and 8148TX Modules B 4 Table B 4 Module LEDs on the Passport 8108GBIC Module B 5 Table B 5 Port LEDs ...

Страница 14: ...xiv 204515 C ...

Страница 15: ...ns and switch startup procedures This guide discusses the Passport 8190SM Passport 8132TX Passport 8148TX and Passport 8108GBIC modules They are referred to collectively as the Passport 8100 modules Each module is referred to specifically when features and functions are unique to that particular model Before You Begin This guide is intended for network administrators with the following background ...

Страница 16: ...u must enter either show ip alerts or show ip routes but not both brackets Indicate optional elements in syntax descriptions Do not type the brackets when entering the command Example If the command syntax is show ip interfaces alerts you can enter either show ip interfaces or show ip interfaces alerts italic text Indicates file and directory names new terms book titles and variables in command sy...

Страница 17: ...t 8000 Series Command Line Interface Switching Operations part number 207308 C Describes the command line interface CLI commands and parameters Most configuration tasks that can be performed using the management software can also be done using the command line interface Networking Concepts for the Passport 8000 Series Switch part number 207307 C Provides general information and description of how ...

Страница 18: ...d connection procedures for the Passport 8002PS DC power supply You can print selected technical manuals and release notes free directly from the Internet Go to the support baynetworks com library tpubs Web address Find the product for which you need documentation Then locate the specific category and model or version for your hardware or software product Use Adobe Acrobat Reader to open the manua...

Страница 19: ...for that distributor or reseller for assistance If you purchased a Nortel Networks service program contact one of the following Nortel Networks Technical Solutions Centers Technical Solutions Center Telephone Number Billerica MA 800 2LANWAN 800 252 6926 Santa Clara CA 800 2LANWAN 800 252 6926 Valbonne France 33 4 92 96 69 68 Sydney Australia 61 2 9927 8800 Tokyo Japan 81 3 5740 1700 ...

Страница 20: ......

Страница 21: ...ement modules The I O modules support different types of Ethernet interfaces with different speeds port counts and media types The following Passport 8100 modules are available Passport 8190SM Switch Management Module management module for the chassis page 1 4 Passport 8132TX Edge Switch Module 32 port 10 100 Mb s Ethernet I O module with expansion slot for optional MDA page 1 8 Passport 8148TX Ed...

Страница 22: ...ine speed Learning rate of 3 million addresses per second peak Address database capacity of up to 16 000 entries at line rate 32 000 entries without flooding Connection to a high speed backplane for forwarding of packets between modules Front panel LEDs for monitoring port activity and module operation Expansion slot for installation of an optional media dependent adapter to provide 100BASE FX fib...

Страница 23: ... I O modules supporting switch to switch trunks and switch to server trunks Ability to remove and install a module hot swap without powering down the switch chassis Port mirroring by port by source and by destination MAC address IP Multicast optimization using Internet Group Management Protocol IGMP snooping RMON port support for the following four groups Alarms Events Statistics History Port for ...

Страница 24: ...e flash memory using the Trivial File Transfer Protocol TFTP Optional PCMCIA card for file management Up to 2 000 VLANs defined by port or network protocol Passport 8190SM Management Module The Passport 8190SM Switch Management Module Figure 1 1 provides centralized management capabilities for the Passport 8010 and 8006 chassis Use this module to configure and manage all 8100 Series modules in the...

Страница 25: ...t 8690SF module provides layer 3 functionality for 8600 Series modules routing switch modules For more information about the Passport 8690SF module refer to Using the Passport 8600 Modules Physical features on the front panel of the Passport 8190SM module include a management port DCE DTE switch for the console port console port modem port reset button PCMCIA card slot and status LEDs Ethernet Man...

Страница 26: ...r communications specifications used by the serial ports refer to Appendix A Technical Specifications Reset Button The recessed reset button on the module allows you to perform a hard reset or reboot of the system PCMCIA Card Slot The Passport 8190SM module provides a PCMCIA card slot for use with an ATA type Sandisk compatible flash memory card The flash memory card provides a convenient way to s...

Страница 27: ...ctivity The CPU bar graph increases when the CPU is actively performing tasks such as learning media access control MAC addresses or interacting with the device management station For detailed information about the LED meanings refer to Appendix B LEDs 9674EA Online Temp 2 Fan 1 Master Power Supply 100 25 50 75 3 2 1 Utilization CPU Link 100 Management 1 2 3 4 5 7 6 1 Management port LEDs 2 CPU ut...

Страница 28: ...sport 8132TX module provides 32 10 100 Mb s autosensing ports that support the IEEE 802 3u autonegotiation standard Each port can operate in full or half duplex mode When a port is connected to another device that also supports the IEEE 802 3u standard the two devices negotiate the best speed and duplex mode of operation The port connectors are 8 pin modular RJ 45 connectors configured as MDI X me...

Страница 29: ...BASE LX MDA 1 port longwave gigabit fiber 8100 4TX MDA 10BASE T 100BASE TX MDA 4 port copper 8100 2FX MDA 100BASE FX MDA 2 port multimode fiber with SC connectors 8100 4FX MDA 100BASE FX MDA 4 port multimode fiber with MT RJ connectors For information about installing MDAs and specifications for each MDA refer to Appendix C Media Dependent Adapters Comm Port The Comm port also called a Console por...

Страница 30: ...formation about LED operation refer to Appendix B LEDs Note Nortel Networks recommends using the Passport 8190SM module to configure and manage your switch The Comm port on the Passport 8132TX module is active only when no Passport 8190SM module is present and when the Passport 8132TX module is operating as the master module The Comm port on the Passport 8132TX module is configured as a data commu...

Страница 31: ... Passport 8148TX Edge Switch Module The port connectors are modular RJ 45 connectors with MDI X wiring This port can be connected to an MDI port for example a workstation or server using a straight through cable The Passport 8108TX module uses 10BASE T 100BASE TX RJ 45 port connectors to connect to 10 Mb s or 100 Mb s Ethernet segments or nodes Refer to Appendix A Technical Specifications for more...

Страница 32: ... I O Module The Passport 8108GBIC I O module Figure 1 7 provides eight bays for installing any of four types of gigabit interface converters GBICs These fiber ports allow you to make riser connection server attachments or interswitch links The following four types of GBICs are available 1000BASE SX 1000BASE LX 1000BASE XD 1000BASE ZX Note Only Nortel Networks qualified GBICs are supported for use ...

Страница 33: ...ng conditions For details of LED operation refer to Appendix B LEDs Figure 1 8 LEDs on the Passport 8108GB Module Redundancy Features A Passport 8000 Series chassis with one or more Passport 8190SM modules and two or more power supplies provides features that support redundant operation in case of certain failures These redundancy features allow you to use this switch in high availability environm...

Страница 34: ...ndant Power Supplies A Passport 8000 Series chassis supports redundant power supplies Both AC and DC power supplies are available and they may be combined in the same chassis The Passport 8010 Chassis with more than six installed modules requires a minimum of two power supplies for a nonredundant configuration A redundant configuration for such a chassis requires three power supplies In a chassis ...

Страница 35: ...r supplies also provide protection against the failure of an individual circuit or power source Table 1 1 Power Supply Hot Swapping Chassis Number of Modules Number of Power Supplies Hot Swap One 8010 Up to 6 1 No 2 Yes 7 to 10 2 No 3 Yes 8006 Up to 6 1 No 2 Yes 3 Yes Note Redundant power supplies are an optional feature not a requirement A single Passport 8000 Series power supply provides adequat...

Страница 36: ...you must make external cable connections Each CPU module must have its own IP address to allow separate management of the separate switch entities When you use Device Manager you can manage either the Passport 8100 Series switch or the Passport 8600 Series switch at a given time The other modules in the chassis are grayed out The Passport 8190SM module provides management only for Passport 8100 Se...

Страница 37: ...tch Configuration For details about configuring a Passport 8100 module refer to Getting Started with the Passport 8100 Management Software Reference for the Passport 8000 Series Management Software Switching Operations and Reference for the Passport 8000 Series Command Line Interface Switching Operations This chapter discusses the following topics Chassis configuration requirements page 2 2 Safety...

Страница 38: ...acement procedure on the switch please note the following safe handling guidelines To prevent damage caused by electrostatic discharge ESD handle the switch chassis and modules only when you the chassis and the chassis modules are properly grounded Nortel Networks recommends using a grounding wrist strap When handling modules do not touch components on the circuit boards always handle modules by t...

Страница 39: ... Series chassis 1 Remove the filler panel from the slot where you will install the module Figure 2 1 Figure 2 1 Removing a Filler Panel 2 Make sure the inserter extractor levers are extended away from the front of the module Figure 2 2 Figure 2 2 Inserter Extractor Levers in Extended Position 9058FA 9397FA ...

Страница 40: ...2 4 204515 C 3 Slide the module into the slot Figure 2 3 Figure 2 3 Inserting a Module 4 Rotate the inserter extractor levers to seat the module backplane connectors Figure 2 4 Figure 2 4 Seating the Backplane Connectors 9398FA 9399FA ...

Страница 41: ...n the chassis power 1 Verify that all power cords are connected properly as described in the installation instructions for the power supplies 2 Turn all the power switches to the On position Note In a chassis with two power supplies in a nonredundant power configuration you must turn on both power supply units within 2 seconds of each other If you wait longer to turn on the second power supply bot...

Страница 42: ...I X EIA Category 3 4 or 5 unshielded twisted pair for 10 Mb s operation EIA Category 5 required for 100 Mb s operation 328 ft 100 m Serial Port Mini DIN 8 RS 232 Not required if Passport 8109SM module is present Passport 8148TX 10 100 Mb s Ethernet Ports RJ 45wired as MDI X EIA Category 3 4 or 5 unshielded twisted pair for 10 Mb s operation EIA Category 5 required for 100 Mb s operation 328 ft 100...

Страница 43: ... same slot and chassis where the same type of module was previously installed the previous configuration is maintained for that module in that slot In all other cases a module inserted into a Passport 8000 series chassis is reset to factory defaults If you remove the switch management module for example to replace it the switch continues switching for up to 2 minutes Then it reboots using the conf...

Страница 44: ...moved 2 Loosen the module retaining screws 3 Rotate the inserter extractor levers to disconnect the module from the backplane connectors 4 Remove the module from the chassis 5 Insert the new module in the chassis and tighten the retaining screws 6 Reconfigure the ports of the new module as necessary 7 Reconnect the cables ...

Страница 45: ...ort page 3 5 Setting system identification page 3 5 Setting system security page 3 6 Sample configuration page 3 8 For information about more advanced configuration topics refer to the following publications Networking Concepts for the Passport 8000 Series Switch Reference for the Passport 8000 Series Management Software Switching Operations Reference for the Passport 8000 Series Command Line Inte...

Страница 46: ...ts in the bottom row are assigned sequential even numbers Figure 3 1 Figure 3 1 Port Numbers on High Density Modules MDA ports are numbered as a continuation of the ports on the module and port numbers on an MDA are in ascending order from left to right For example the far left MDA port in a Passport 8132TX module is port 33 Gigabit MDAs with redundant PHYs are regarded as a single port To specify...

Страница 47: ...les which check for the presence of a Passport 8190SM module in the chassis When the Passport 8190SM module has completed its boot process the I O modules transmit a load request Messages on the console screen indicate the request and the completion of the image load Then the I O modules reboot using the newly loaded image The entire boot sequence for the switch can take up to one minute When the ...

Страница 48: ...Password Read Only Allows only viewing of configuration and status information Is equivalent to SNMP read only community access ro ro Layer 2 read write Allows viewing and changing configuration and status information for layer 2 bridging switching functions l2 l2 Read Write Allows viewing and changing configuration and status information across the switch does not allow changing security and pass...

Страница 49: ... system name contact person and location To set the system identification 1 Specify the system name using the command config sys set name prompt where prompt is an ASCII string specifying the system name and box or root level prompt 2 Specify the name of the contact person for the switch using the command config sys set contact contact where contact is an ASCII string specifying the name of the pe...

Страница 50: ... Write login and or password config cli password rw username password changes the Read Write login and or password config cli password rwa username password changes the Read Write All login and or password where username is the login name password is the password associated with the login name 2 Change SNMP community strings using the command config sys set snmp community ro rw l2 rwa commstr wher...

Страница 51: ...ted with the login name up to 20 characters long To enable or disable Telnet access you set flags from the boot monitor CLI You can access the boot monitor CLI while the switch is booting To set up Telnet access 1 While the switch is booting press any key to interrupt the autoboot process 2 Enable or disable Telnet access using the command flags telnetd true false where true enables Telnet access ...

Страница 52: ...P address for management Specify a default gateway address or default route Test connectivity To configure the switch as a layer 2 bridging switching device 1 Confirm that all ports are in the default VLAN using the command show vlan info ports The display shows the VlanId 1 and lists the port members 2 To assign an IP address for management use the command config bootconfig net mgmt ip ipaddr mas...

Страница 53: ...the following Boot Monitor CLI command to specify the default route net mgmt route net 0 0 0 0 ipaddr Use the following Run Time CLI command to specify the default route config bootconfig net mgmt route net 0 0 0 0 ipaddr In each of these commands ipaddr specifies the IP address of the default gateway 4 To save the configuration enter save config Your Passport 8100 switch now has an IP address and...

Страница 54: ......

Страница 55: ... Installation issues page 4 7 Normal Power Up Sequence In a normal power up sequence the LEDs display as follows 1 When power is applied to the switch the green LED on each power supply and fan tray turns on within 5 seconds 2 Each module initiates a self test during which the port and module LEDs display various patterns to indicate the progress of the self test 3 Upon successful completion of th...

Страница 56: ...software does not recognize the presence of any I O modules in the switch the device view in Device Manager for example shows a switch with only a management module installed This situation can occur when no I O module is installed in slot 1 or slot 2 of the chassis A Passport 8000 Series chassis must have an I O module installed in slot 1 or slot 2 of the chassis to provide bus master functions f...

Страница 57: ...r indications of communication problems Use the boot command to download a new software image The Master LED on a module in slot 1 or slot 2 is yellow This module has detected system clock generation failure on its own circuitry Replace the module make sure it is in the correct slot Note This LED refers only to the module in slot 1 or slot 2 that provides the clock function for the switch The Faul...

Страница 58: ...BASE T station that has the sending pair attached to its receiving pair and vice versa In this way the two nodes can exchange data If the two nodes are wired alike they both attempt to send data out on the same RJ 45 pins In such a case a straight through cable would not work However a crossover cable would operate normally The Passport 8100 Series modules are designed to have Ethernet NICs connec...

Страница 59: ...00 modules negotiate port speeds according to the IEEE 802 3u autonegotiating standard The switch adjusts autonegotiates its port speed and duplex mode to match the best service provided by the connected station up to 100 Mb s in full duplex mode The following autonegotiation problems can occur If the connected station uses a form of autonegotiation that is not compatible with the IEEE 802 3u auto...

Страница 60: ...ditional steps 1 Using the CLI disable the autonegotiation feature at the connected station 2 Manually set the speed duplex mode of the connected station to the same speed duplex mode you have manually set for the Passport 8100 module port Port Interface Verify that the devices are connected using the appropriate crossover or straight through cable For information about appropriate cables refer to...

Страница 61: ...ss control MAC station address and an IP address The MAC station addresses are unique because each address contains the Nortel Networks manufacturer ID and node ID codes A valid IP address is not required for normal switching operation or if you are managing the switch from a console However for management over the network SNMP or Telnet session a valid IP address is required You can change the IP...

Страница 62: ......

Страница 63: ...nector types and where appropriate pin assignments Required cables MDI and MDI X connections Declaration of Conformity General Specifications Standards Supported IEEE 802 3 CSMA CD ISO IEC 8802 3 IEEE 802 3i 10BASE T ISO IEC 8802 3 IEEE 802 3u 100BASE TX ISO IEC 8802 3 IEEE 802 1D MAC Bridges ISO IEC 10038 IEEE 802 1p Prioritization IEEE 802 1Q VLAN Tagging IEEE 802 1z Gigabit IEEE 802 3z 1000BASE...

Страница 64: ...ltitude 3000 m 10 000 ft maximum Free Fall Drop ISO 4180 s NSTA 1A Vibration IEC 68 2 6 34 Shock Bump IEC 68 2 27 29 Performance Specifications 64 byte packets Aggregate Throughput 3 000 000 pps maximum Switched Forwarding Rates For 10 Mb s 14 880 pps maximum For 100 Mb s 148 810 pps maximum For 1000 Mb s 1 488 100 pps maximum Latency 9 ms Address Database Size Addressing 48 bit MAC address Frame ...

Страница 65: ...997 Physical Specifications Height 1 5 in 3 8 cm Width 15 4 in 39 1 cm Depth 18 5 in 47 0 cm Weight 7 lb 3 15 kg Electrical Specifications Input Current 75 W Thermal Rating 250 BTU hr maximum MTBF Rating 229 623 hr Connector Types Ethernet Management port RJ 45 connector wired as MDI X Table A 1 Console port DB 9 connector Table A 2 Modem port DB 9 connector Table A 3 Required Cables Ethernet Mana...

Страница 66: ...the port to DTE left or DCE right Default settings for this port are 9600 bps 8 data bits no parity and one stop bit Because the Console port expects to receive Data Set Ready DSR and Clear To Send CTS signals before transmitting these control lines are required in the cabling The Console port does not support any inbound flow control that is the port does not toggle control lines to indicate an i...

Страница 67: ...nsmit cable between the Modem port and a modem or terminal server The cable should have the pin assignments listed in Table A 3 Table A 2 Pin Assignments in the Passport 8190SM Console Port Connector Pin Number DCE Signal DTE Signal 2 RXD TXD 3 TXD RXD 4 DTR DSR 5 GND GND 6 DSR DTR 7 RTS CTS 9 CTS RTS Table A 3 DTE to DCE Pin Assignments Switch Modem Signal Pin Number DCE DB 9 Pin Number DCE DB 25...

Страница 68: ...tions Input Current 75 W maximum Thermal Rating 250 BTU hr maximum MTBF Rating 122 000 hr Connector Type 10 100 Ethernet Ports RJ 45 connector wired as MDI X Table A 4 Comm Port Mini DIN Cable Specifications Type Category 3 4 or 5 UTP cable 10 Mb s operation Category 5 UTP cable 100 Mb s operation Maximum Distance 328 ft 100 m Table A 4 Passport 8132TX Port Pinouts Connector Pin Number Signal 1 In...

Страница 69: ... Passport 8132TX module is active only when the chassis has no installed Passport 8190SM module You should not use this port for managing the switch if you are using software version 2 0 or later 450 1SR MDA 450 1SX MDA Required Cable Multimode fiber optic Maximum distance 1804 ft 550 m Wavelength 850 nm Average Transmit Output Power 9 5 to 4 dBm Average Receiver Sensitivity 17 dBm minimum 450 1LR...

Страница 70: ... Specifications Input Current 75 W maximum Thermal Rating 250 BTU hr maximum MTBF Rating 72 213 Connector Type RJ 45 connector wired as MDI X Table A 5 Cable Specifications Type Category 3 4 or 5 UTP cable 10 Mb s operation Category 5 UTP cable 100 Mb s operation Maximum Distance 328 ft 100 m Table A 5 Passport 8148TX Port Pinouts Connector Pin Number Signal 1 Input receive data RX 2 Input receive...

Страница 71: ...cm Width 15 4 in 39 1 cm Depth 18 5 in 47 0 cm Weight 8 lb 4 kg Electrical Specifications Input Current 65 W maximum Thermal Rating 224 BTU hr maximum MTBF Rating 93 284 hr Connector Type Duplex SC Physical Specifications Height 12 mm Width 30 mm Depth 65 mm Weight Varies with GBIC type Connector Type Duplex SC ...

Страница 72: ...ransmit Output Power 9 5 to 4 dBm Average Receiver Sensitivity 17 dBm minimum Cable Specifications Type 62 5 µm multimode fiber or 9 µm single mode fiber Note Multimode fiber may require a DMD patch cord Maximum Distance Single mode fiber 32 810 ft 10 km Multimode fiber 1804 ft 550 m Optical Specifications Wavelength 1300 nm FP laser diode Average Transmit Output Power 5 2 to 0 dBm Average Receive...

Страница 73: ...ical Specifications Wavelength 1550 nm DFB laser diode Average Transmit Output Power 5 2 to 0 dBm Average Receiver Sensitivity 24 dBm Cable Specifications Type 9 µm single mode fiber Maximum Distance 43 mi 70 km Note For a shorter link distance you may need an in line attenuator to prevent overloading the receiver Optical Specifications Wavelength 1550 nm DFB laser diode Average Transmit Output Po...

Страница 74: ...the crossover function internally The Passport 8100 modules use MDI X ports that allow you to connect directly to end stations without using crossover cables Figure A 1 Ports that implement the crossover function internally are known as MDI X ports where X refers to the crossover function Figure A 1 MDI X to MDI Cable Connections 1 8 1 8 8 1 8 1 RX RX TX TX TX TX RX RX MDI X port Passport 8000 swi...

Страница 75: ...h ISO IEC Guide 22 and EN45014 The declaration identifies the product models the Nortel Networks name and address and the specifications recognized by the European community As stated in the Declaration of Conformity the Passport 8100 modules comply with the provisions of Council Directives 89 336 EEC and 73 23 EEC 1 8 1 8 8 1 8 1 RX RX TX TX RX RX TX TX MDI X port Passport 8000 switch Switch or h...

Страница 76: ......

Страница 77: ...08GBIC Module page B 4 Passport 8190SM Switch Management Module Figure B 1 shows the LEDs on the Passport 8190SM module Table B 1 describes the operation of these LEDs Figure B 1 LEDs on the Passport 8190SM Module 9674EA Online Temp 2 Fan 1 Master Power Supply 100 25 50 75 3 2 1 Utilization CPU Link 100 Management 1 2 3 4 5 7 6 1 Management port LEDs 2 CPU utilization LEDs 3 Fan LEDs 4 Temp LED 5 ...

Страница 78: ...n the specified position is not turned on Green Steady The specified power supply is operating normally Amber Steady The specified power supply has a fault Fan 1 2 Green Steady The specified fan is operating normally Amber Steady The specified fan has failed Temp Green Steady The temperature is normal for switch operation Amber Steady The maximum operating temperature has been exceeded Master Off ...

Страница 79: ...o indicate module and system operating conditions Table B 2 In addition each port has two LEDs to indicate data speed and link status Table B 3 Figure B 2 shows the locations of the LEDs Figure B 2 LEDs on the Passport 8132TX and 8148TX Modules 1 2 3 9120EA 1 Module LEDs 2 Port LEDs Speed 3 Port LEDs Link Activity ...

Страница 80: ...Steady This module has detected system clock generation failure on its own circuitry Off This module is not providing the system clock for the switch You can pull this module out of the chassis without resetting the switch Online Green Steady The module is functioning normally and is in switching mode Green Blinking The module is running diagnostic tests Yellow Steady The module is not in switchin...

Страница 81: ...n pull this module out of the chassis without resetting the switch Online Off The switch power is off Or The power has been turned on and the module is going through its power on self test and software initialization A module in this state is not yet functional Amber Steady The module failed its power on self test Green Steady The module has completed its power on self test and software initializa...

Страница 82: ......

Страница 83: ...DA 1 port shortwave gigabit fiber 450 1LR MDA 1000BASE LX MDA 1 port longwave gigabit fiber with 1 redundant port 450 1LX MDA 100BASE LX MDA 1 port longwave gigabit fiber 8100 4TX MDA 10BASE T 100BASE TX MDA 4 port copper 8100 2FX MDA 100BASE FX MDA 2 port multimode fiber with SC connectors 8100 4FX MDA 100BASE FX MDA 4 port multimode fiber with MT RJ connectors Nortel Networks continually adds ne...

Страница 84: ... Two longwave gigabit MDAs Figure C 2 The 450 1LR MDA is a single MAC MDA with a separate redundant Phy backup Phy port The 450 1LX MDA is a single Phy MDA These MDAs use longwave 1300 nm fiber optic connectors to connect devices over single mode 3 kilometer or multimode 550 meters fiber optic cable Figure C 1 1000BASE SX Shortwave Gigabit MDA Front Panels 1000BASE SX TX RX Phy Link Activity 450 1...

Страница 85: ...s bad or there is no connection to this port Phy Select Phy selection LEDs Green On The corresponding Phy port is selected Off The corresponding Phy port is in backup mode Activity Port activity LEDs Green Blinking Indicates network activity level for the corresponding port A high level of network activity can cause LEDs to appear to be on continuously 1000BASE LX TX RX Phy Link Activity 450 1LX M...

Страница 86: ...nk Communication link LEDs Green On A valid communication link is established Green Blinking The corresponding port is management disabled Off The communication link connection is bad or there is no connection to this port Phy Select Phy selection LEDs Green On The corresponding Phy port is selected Off The corresponding Phy port is in backup mode Activity Port activity LEDs Green Blinking Indicat...

Страница 87: ...Type Color State Meaning 100 100BASE TX port status LEDs Green On The corresponding port is set to operate at 100 Mb s Green Blinking The corresponding port is management disabled Off The link connection is bad or there is no connection to this port 10 10BASE T port status LEDs Green On The corresponding port is set to operate at 10 Mb s Green Blinking The corresponding port is management disabled...

Страница 88: ...e is no connection to this port F Dx Full duplex port status LEDs Green On The corresponding port is in full duplex mode Green Off The corresponding port is in half duplex mode Activity Port activity LEDs Green Blinking Indicates the network activity level for the corresponding port A high level of network activity can cause LEDs to appear to be on continuously RX TX 100BASE FX RX TX 100BASE FX Ac...

Страница 89: ... disconnect the module from the chassis backplane connector 3 Loosen the thumbscrews and remove the filler panel or previously installed MDA from the MDA slot 4 Insert the MDA into the slot Figure C 5 taking care to slide the MDA onto the guides provided on the module backing Figure C 5 Installing an MDA Note The MDAs are hot swappable in an operating Passport 8132TX module however the module rese...

Страница 90: ...e MDA in the module by tightening the thumbscrews on the MDA front panel 7 Use the inserter extractor levers to reseat the module backplane connector 8 Tighten the module retaining screws 9 Attach devices to the MDA ports Note The IEEE 802 3u specification requires that all ports operating at 100 Mb s use only Category 5 unshielded twisted pair UTP cabling ...

Страница 91: ...r over distances up to 550 meters or single mode fiber over distances up to 10 kilometers km 100BASE XD uses single mode fiber over distances up to 50 km 100BASE ZX uses single mode fiber over distances up to 70 km GBICs are available in two styles Figure D 1 One type has two spring tabs at the front of the GBIC the other type has an extractor handle on the front Figure D 1 Types of GBICs GBICs ar...

Страница 92: ... GBIC from its protective packaging 2 Insert the GBIC into the slot on the module Figure D 2 GBICs are keyed to prevent improper insertion If the GBIC resists pressure do not force it Remove it turn it over and reinsert it Figure D 2 Installing a GBIC 3 Press on the front of the GBIC until it snaps into place 4 Remove the rubber plug to connect cables Warning Fiber optic equipment can emit laser o...

Страница 93: ...1 If the GBIC has spring tabs press in on the tabs on each side of the GBIC as you pull the GBIC out of the bay Figure D 3 Figure D 3 Removing a GBIC 2 If the GBIC has an extractor handle grasp the handle and pull firmly to remove the GBIC from the bay 9704FA ...

Страница 94: ......

Страница 95: ...on 1 RFC 1213 Network Management of TCP IP MIB II RFCs 1271 and 1757 RMON RFC 1493 Bridge MIB RFC 1573 IANA If Type RFC 1643 Ether like MIB RFC 1723 RIP version 2 RFC 1850 OSPF MIB RFC 2131 DHCP RFC 2233 IANA If Type RFC 2236 IGMP version 2 IEEE 802 1D Standard for Spanning Tree Protocol IEEE 802 3 Ethernet IEEE 802 1Q VLAN Tagging Enterprise MIB located on the Passport 8000 Series Software CD ...

Страница 96: ......

Страница 97: ... autonegotiation troubleshooting 4 5 autosensing ports 1 3 B boot sequence 3 3 C cable Category 5 4 4 crossover 4 4 A 12 fiber 4 5 fiber optic A 6 straight through 2 6 4 4 A 5 troubleshooting 4 4 UTP A 6 A 8 cable lengths 2 6 cables connecting 2 6 chassis configuration requirements 2 2 chassis slots dedicated 2 2 combining module types 1 16 Comm port 1 9 configuration saving 3 9 connections MDI X ...

Страница 98: ... 12 gigabit 1 8 gigabit interface converter See GBIC H hot swapping MDAs C 7 modules 2 7 power supply 1 14 I identification parameters system 3 5 IGMP 1 3 installation process 2 3 troubleshooting 4 7 IP address assigning 3 5 3 8 troubleshooting 4 7 L layer 2 read write security access 3 4 layer 2 switching 3 8 LEDs MDA location C 2 C 3 C 4 meanings C 3 C 4 C 5 Passport 8132TX module location 1 10 ...

Страница 99: ...Select LED C 3 C 4 pin assignments 10 100 Mb s ports A 6 A 8 Console port A 5 Ethernet Management port A 4 mini DIN connector A 7 Modem port A 5 port connections troubleshooting 4 4 port mirroring 1 3 port numbers 3 2 ports 10 100 Mb s 1 11 A 6 A 8 autosensing 1 8 Console A 4 Ethernet Management 1 5 A 4 MDI X MDI connections A 12 Modem A 5 serial 1 6 power configuration nonredundant 1 14 power sou...

Страница 100: ...ough cable 2 6 4 4 A 5 support Nortel Networks xix switch configuration basic steps 3 8 switch description 1 1 switch management module replacing 2 7 system clock B 4 system clock failure 4 3 system identification 3 5 system log 4 3 system parameters setting 3 5 system security setting 3 6 T tagging 1 3 technical publications xviii technical support xix Telnet access 3 7 Temp LED B 2 text conventi...

Отзывы: