Page 36 RHC 8000 EN April 2019 D301207 Issue C
are dependent upon the local environment
where the heater is installed. All gas
appliances should be serviced at least once
a year.
In case of any damage to the appliance, it
must be shut down completely and checked
by an appropriately qualified person.
In the event of difficulties in resolving any
of these matters, please do not hesitate to
contact the official distributor.
NEVER SWITCH OFF ELECTRICITY SUPPLY
TO THE AIR HEATER WITHOUT FIRST
CLOSING THE GAS TAP
11. Health & Safety
Statement
12.1 General
The manufacturer hereby provide the
following information on substances
hazardous to health.
Product range reference RHC 8000(M)
Series air heaters
11.2 Cautionary Note
During first firing some smoking may occur,
this is due to the burning off of protective/
lubricating oils used during appliance
production. Most of this will have been
removed during the production testing
process. It is a wise precaution to ensure
that adequate ventilation is provided
during the initial firing and throughout the
commissioning period, this is particularly
important if the discharge air is to blow into
a confined space. This smoking does not
constitute a poison hazard.
11.3 Declaration
RHC products contain no asbestos; copper
is not employed in as carrying components;
solder which has a melting point below
450°C is not used; paints for corrosion
protection and decoration are heat cured
and contain no lead.
The above appliances meet the
Electrical Safety requirements of EN
60335-1.
11.4 Miscellaneous
Small quantities of adhesives and sealants
used in the product are dried and cured and
present no known hazard.
11.5 Insulation and Seals.
Material: Alumino - silicon fiber - crane
glass
Description: Tapes
Known hazards
: Some people can suffer
reddening and itching of the skin. Fiber
entry into the eyes will cause foreign body
irritation. Inhalation will cause irritation to
the respiratory tract.
Precautions:
Wear protective gloves when
handling.
People with a history of skin complaints
may be susceptible to irritation.
Dust levels are only likely when the material
is abraded.
In general normal handling and use for this
purpose will not present discomfort. Follow
good hygiene practices, wash hands before
consuming food or using the toilet.
First Aid:
Medical attention must be
sought following eye contact or prolonged
reddening of the skin.
11.6 Thermostat. Thermal
Overheat (limit) Control (LC3)
Material: Illuminating Kerosene.
Description:
Sealed phial contains a small
quantity in liquid form.
Recognition:
Colourless liquid, paraffin oil/
petroleum hydrocarbon odour.