Shaded boxes indicate fl ooded conditions.
Rated design values. The suction pressure will vary from design value if indoor air fl ow, entering dry bulb,
or entering wet bulb temperatures are lower than design.
1. All pressures are listed in psig and all temperatures in ° F
2. Discharge temperatures greater than charted values indicate an undercharged system.
REFRIGERANT CHARGING TABLES
Table 5. Charging Table for JS5BD-018 Series (1.5 Ton Units)
Suct.
Press.
OUTDOOR TEMPERATURE (° F)
70
75
80
85
90
95
100
105
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
74
156
119
76
159
124
173
126
78
161
130
175
131
190
133
80
161
139
177
136
192
138
206
139
82
165
142
178
143
194
142
208
144
223
145
84
182
146
195
148
211
148
225
150
239
151
86
199
151
213
153
227
154
241
156
256
157
88
216
157
230
158
243
160
258
161
272
163
90
220
160
233
162
247
164
260
165
274
166
92
237
166
250
168
264
169
276
170
94
254
172
267
174
281
175
96
271
178
284
180
98
288
184
100
Table 6. Charging Table for JS5BD-024KB Series (2 Ton Units with Microchannel Coil)
Suct.
Press.
OUTDOOR TEMPERATURE (° F)
70
75
80
85
90
95
100
105
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
Liq.
Press.
Dis.
Temp.
71
149
103
73
152
109
167
115
75
154
114
170
120
185
126
77
154
124
172
125
187
131
203
137
79
157
126
172
132
190
135
205
141
221
147
81
176
135
191
141
207
146
223
151
239
157
83
194
145
209
150
225
156
241
162
257
167
85
213
154
228
160
243
166
259
171
274
177
87
216
158
231
164
246
170
261
175
276
181
89
235
168
250
174
265
180
278
185
91
253
178
268
184
283
190
93
272
188
287
194
95
290
199
97