8. Programming Mode
Loopback
If the master code is either not working or forgotten, power
down the system, connect the wire harness as shown in Figure 12
below, and then power the system up again. Next, change your
master code and power down the system and restore the wire har-
ness to its original configuration and power the system back up.
First, disconnect power from the system. Next, connect the
White/Yellow wire to the Brown (REX) and White wire as shown
in Figure 12. Finally, power up the keypad again.
Figure 12 Programming Mode Loopback Standalone
IEI 232e Standalone Installation/Programming Manual
20
Document # 6054004, Rev. 2.1