2. Specifications

Parameter

Range/Description

Voltage

10-30 VDC,
12-24 VAC

Current

75mA@10VDC,
100mA@30VDC,
125mA@12VAC, and
200mA@24VAC
Add 20 mA for each alarm relay

Environment

Indoor and Outdoor

Temperature Tolerance

-20 °F to 130 °F

Dimensions

4.5" H x 2.75" W x 0.60" D

Main Relay (Form C)

Contact Rating:

2A @
30VAC/DC

Alarm Relays: Alarm Shunt,
Propped Door, Forced Door
Relays (Form C)

Contact Rating:

1A @
24V AC/DC

IEI 232e Standalone Installation/Programming Manual

Document # 6054004, Rev. 2.1

3

Содержание IEI 232e Standalone

Страница 1: ...e Keypad to an Electric Strike Fail Secure 5 4 Shunting a Normally Closed Zone 5 5 Wiring Remote Trigger as Request to Exit REX Button and Door Contacts 5 6 Installing the Plug On Relay Board 5 7 Wiri...

Страница 2: ...cations It features output relays to release the door lock to shunt an alarm zone and to trigger both a propped or forced door alert Also the 232e Keypad contains in puts for door monitor and REX It a...

Страница 3: ...A for each alarm relay Environment Indoor and Outdoor Temperature Tolerance 20 F to 130 F Dimensions 4 5 H x 2 75 W x 0 60 D Main Relay Form C Contact Rating 2A 30VAC DC Alarm Relays Alarm Shunt Propp...

Страница 4: ...pad A minimum of three user codes must be programmed into the key pad for controlling access 3 1 Tamper Requirements To meet U L requirements a U L Listed tamper switch must be in stalled in the singl...

Страница 5: ...Figure 1 Mounting a Sentrol 3012 Tamper Switch Figure 2 Mounting a Sentrol 3025T Tamper Switch IEI 232e Standalone Installation Programming Manual Document 6054004 Rev 2 1 5...

Страница 6: ...of this manual and on the unit s container Mounting height can vary depending on requirements An appropri ate range is typically between 48 and 52 inches on center off the floor For outdoor installati...

Страница 7: ...r REX 6 White Orange Loop Common 7 White Door Loop Monitor 8 Green Main Relay Normally Open 9 Blue Main Relay Common 10 Gray Main Relay Normally Closed Figure 4 232e Connector and Wire Harness NOTE Fo...

Страница 8: ...ower supply 4 3 Wiring the 232e Keypad to an Electric Strike Fail Secure Use the following steps to connect the 232e keypad to an electric strike fail secure see Figure 6 for reference 1 Connect the r...

Страница 9: ...ue wire common to the common connection on the door position switch 2 Connect the green wire normally open to the normally closed connection on the door position switch Figure 6 Wiring 232e Keypad to...

Страница 10: ...hite wire door loop to the normally closed connection on the door switch NOTE By default the REX function operates the virtual lock out put only but this can be changed using command 49 In addition th...

Страница 11: ...1 Propped Door K3 P2 Forced Door K4 P3 Use the wire harnesses supplied with the relay board to connect to the relays The wire colors are shown in the table below Wire Color Relay Connection Green Norm...

Страница 12: ...y Board To install the relay board plug the connector onto P3 on the key pad The relay must face up towards the keypad wire harness con nector P2 IEI 232e Standalone Installation Programming Manual 12...

Страница 13: ...witch 2 Wiring the propped door alarm Using P2 K3 connect the green wire normally open to the positive on the alarm device Connect the blue wire common to the positive on the power supply Connect the...

Страница 14: ...keypad 7890 123456 If all 12 keypresses are accepted the keypad enters self test mode The LEDs alternate green yellow and red followed by the sounder beeping three times 2 Verify that the master code...

Страница 15: ...ons time Propped Door Time rounded down to nearest 10 s of seconds entered as 00 10 through 990 defaults to 30 seconds entering a time of zero disables the function Command 45 Set Forced Door Time Opt...

Страница 16: ...elete or disable the master code or supervisor code itself Add User user location code code Add User with Specific Unlock Time unlock time user location code code This command is used to program a use...

Страница 17: ...uto Entry Suspend Just enter the key prior to your code followed by the key Example 23456 if the master code is four digits Error Lockout When enabled the keypad keeps track of the number of consecuti...

Страница 18: ...reshold 1 through 50 defaults to 3 3 error lockout duration 1 through 255 defaults to 10 Command 40 Reset defaults only 40 00000 00000 master code all keypad options and parameters Command 46 Erase Us...

Страница 19: ...he voltage to between 12 24V The master code does not work Perform the programming mode loopback and reset the master code using the programming command No LEDs are lit on the keypad Power is not reac...

Страница 20: ...ter code and power down the system and restore the wire har ness to its original configuration and power the system back up First disconnect power from the system Next connect the White Yellow wire to...

Страница 21: ...after obtaining IEI s Return Material Authorization IEI will not be liable to the purchaser or any one else for incidental or consequential damages arising from any defect in or malfunction of its pro...

Страница 22: ......

Страница 23: ......

Страница 24: ......

Отзывы: