6.3 Programming Keypad Options
Command/Action
Keys to Enter/Details
Command 30.
Enable/Disable
keypad options
30 # option # enable/disable # * *
Option
Set/Clear
0 - audio keypress feedback
0=disabled,
1=ENABLED
1 - visual keypress feedback
0=disabled,
1=ENABLED
2 - auto-entry enable
0=DISABLED,
1=enabled
3 - error lockout
0=disabled,
1=ENABLED
6 - keypad illumination
0=disabled,
1=ENABLED
7 - keypad dimming
0=disabled,
1=ENABLED
8 - REX operation
0=only when door loop closed
1=always
Defaults are in bold.
Auto-entry
When auto-entry is enabled, users with
codes the same length as the master code
do not have to press the * key after
entering their code. If you have a code
greater than the master code, you can use
Auto-Entry Suspend. Just enter the # key
prior to your code followed by the * key.
Example:
# 23456 * if the master code is four digits.
Error Lockout
When enabled, the keypad keeps track of
the number of consecutive invalid codes
entered, including attempts to access
program mode. When the threshold is
reached, the yellow LED turns on solid and
the keypad no longer responds to key
presses for the programmed time duration.
The count is reset by entering a valid code,
including entering program mode. The error
lockout threshold and duration is
programmed with command 32.
Keypad Illumination
Keypad backlighting can be enabled or
disabled.
Keypad Dimming
When enabled, the backlighting illumination
level decreases 15 seconds after the last
key press. When disabled, the backlighting
remains at full illumination at all times.
IEI 232e Standalone Installation/Programming Manual
Document # 6054004, Rev. 2.1
17