Troubleshooting Guide
●
Monthly, test the obstruction and entrapment protection systems.
●
Monthly, service the gate operator (make sure the power switch is OFF). Clean extended operator arm with a soft,
dry clean cloth.
●
On all gates weighing 250 lb. or more, routinely grease the ball bearing hinges at least 4 times a year; more
frequently if the gates are near a coastal area.
●
Monthly, turn off the power switch and disconnect the Mighty Mule and move the gate to make sure the gate is
moving freely without sticking or binding. Lubricate the hinges or repair the gate as required before reattaching
the Mighty Mule.
●
Monthly, check the gate system for potential entrapments from new landscaping or construction. Eliminate or
guard as required.
●
Monthly, check that the warning signs are mounted on each side of the gate and clearly visible. Replace the signs
if they are missing or damaged.
●
Replace batteries every 2-3 years and properly recycle old batteries.
If your gate operator does not function properly after it is installed, use this guide before calling the Nortek
Security & Control Service Department.
Audible Feedback
Maintenance
Symptom
Diagnosis
Check
1 or more short beeps upon
power up
Circuit board powered up &
ready
h
Normal operation
Rapid beeping
h
No battery preset
h
Circuit board senses an
obstruction
h
Blown fuse in battery
harness cable
h
Gate for adequate maintenance, free swinging, level
and plumb
h
Stall Force adjustment
h
Disconnect obstruction detection devices
h
Battery connections
h
Check fuse
1 beep every 20 seconds
Low battery
h
Check fuse
h
Battery harness connections
h
Battery under load or inadequate charge
h
AC output at 120 Vac, transformer output at 19 Vdc
h
Solar panel(s) output based on weather conditions
h
Wiring from charge source to control board, verify
correct polarity
2 beeps every 2 seconds
Position sensor is short circuit.
h
Arm power cable for damage
1 beep every 2 seconds
Position sensor is open circuit.
h
Arm power cable for damage
1 beep when attempting to
run the gate
Blown fuse
Battery is low or damaged
Loose connection
h
Check fuses
h
Battery harness connections
h
Battery under load or inadequate charge
Additional information can be found by contacting Nortek Security & Control.