HD272 Installation Instructions
25
Step 3
Lay the measured length of low voltage wire
in a trench following a path from the selected
electrical outlet to the control box. Wires coming
up from the ground should be run through PVC
conduit to protect them from lawn mower blades,
weed eaters, and grazing animals. Be sure to bury
the wire laid in the trench.
Step 4
Bring enough wire up through the PVC conduit to reach the control board.
Step 5
Strip
3
/
16
" off the ends of the low voltage wire and twist tightly. Attach
these ends to the CHARGER OR SOLAR terminals located on the terminal
block). Be certain not to let the exposed wires touch each other!
Insert one transformer wire into a CHARGER OR SOLAR terminal. Insert
the other transformer wire into the remaining CHARGER OR SOLAR
terminal. The transformer wires can be connected to the CHARGER OR
SOLAR terminals regardless of color/polarity.
Tighten set screws against exposed end of wires. A dab of household
petroleum jelly on each terminal will help prevent corrosion.
First Gate Opener
Run 1000' (max.) of low
voltage wire to control
box from transformer
(wire not included).
120 Volt indoor
Transformer
(surge protector
not supplied)
PVC conduit (not included)
to protect wire from lawn
mowers and weed eaters.
Control Box
VAR5
VAR6
K1
PF1
K2
BATT +
BATT –
K3
K4
VAR4
VAR3
VAR2
VAR1
MIN
MAX OFF
≤JP1
REMOVE JUMPER FOR
PUSH TO OPEN OPTION
120
SEC.
G
TO Inc.
Tallahassee, FL
R4722
STALL FORCE
OPEN < JOG > CLOSE
PWR.
SET
LIMIT
1st OPR.
2nd OPR.
STATUS
AUTO CLOSE
SFTY.
EXIT
CYCLE
EDGE
SENSOR
COMMON
LOCK+
LOCK–
WHT
GRN
RED
BLK
WHT
GRN
SECOND OPR
.
FIRST OPR
.
RED
BLK
CHARGE
ON OFF
Low Voltage Wire from
Transformer or Solar
OR
SOLA
VAR6
BATT
+
K3
K4
WHT
GRN
SECOND OPR
.
RED
BLK
OR
SOLA
CHARGE
ON OFF
Low Voltage Wire
from Transformer
or Solar Panel