55
Decommissioning
Nortec EL/RS Outdoor
2584597_B_EN_1705
9
Decommissioning
9.1
General
If the Nortec EL/RS Outdoor humidifier needs to be removed from service (for disposal or long-term
storage), strictly follow all instructions in this chapter.
Personnel Qualifications
Decommissioning of the Nortec EL/RS Outdoor humidifier must only be performed by a qualified service
technician authorized by the customer. It is the customer's responsibility to verify qualifications of the
personnel.
Safety
Decommissioning of the Nortec EL/RS Outdoor humidifier will require personnel to access the inside
of the control and plumbing cabinets in the humidifier, which may expose personnel and equipment to
safety hazards.
Observe all other safety precautions described in
, as well as the respective
Nortec EL/Nortec RS operation and maintenance manual.
9.2
Removal from Service for Disposal or Long-term Storage
Remove the Nortec EL/RS Outdoor humidifier from service (for disposal or long-term storage) as follows:
1. Drain the steam cylinder (and the scale tank on the RS-OC unit), and shut down the humidifier –
refer to the respective Nortec EL/Nortec RS operation and maintenance manual. Follow all safety
precautions.
2. Disconnect and remove the power supply to the Nortec EL/RS Outdoor humidifier. Refer to
Enclosure Wiring Diagram" on page 40
, and the wiring diagrams in the Nortec EL/Nortec RS manuals.
3. Disconnect and remove the control signal inputs from the humidifier.
4. Disconnect the steam and condensate lines, and empty out all fluids.
5. Disconnect the water and drain connections to the humidifier.
WARNING!
Heavy object – risk of personal injury and damage to equipment!
Prevention:
Use a forklift or crane to lift the humidifier, and protect the unit from damage by
tethers and other lifting equipment.
6. Carefully remove the humidifier from its mounting surface.
7. Cap the pipe chases.
8. If the Nortec EL/RS Outdoor humidifier is to be put into long-term storage, store the humidifier in its
original packaging inside a protected area that meets the following requirements:
• Room temperature: 41 to 104 °F (5 to 40 °C)
• Room humidity: 10 to 75% RH
9. If the Nortec EL/RS Outdoor humidifier is to be disposed off, refer to
"Disposal/Recycling" on page 56
.
Содержание EL SERIES
Страница 10: ...6 Receiving and Storage 2584597_B_EN_1705 Nortec EL RS Outdoor This page intentionally left blank ...
Страница 16: ...12 Product Overview 2584597_B_EN_1705 Nortec EL RS Outdoor This page intentionally left blank ...
Страница 46: ...42 Commissioning 2584597_B_EN_1705 Nortec EL RS Outdoor This page intentionally left blank ...
Страница 58: ...54 2584597_B_EN_1705 Nortec EL RS Outdoor This page intentionally left blank ...