Item

Check

• When installing the unit on a balcony, etc., secure an

evacuation route of 24" or more in width.

• Provide clearance of 24" or more in front of the unit to

facilitate inspection and repair. Do install the unit such as
the wall of the second floor where the unit is out of reach.

• When installing the unit in a common side corridor, pro-

vide a clearance of 47" or more in front of the unit.

• Set the bottom edge of the exhaust port about 84" from

the corridor floor.

Handrail

common side
corridor

balcony, etc.

Handrail

about 84"

• Maintain the following clearance from both combustible

and non-combustible materials.

* ( ) indicates the distance when installing a heat insulat-

ing board (incombustible material other than metal, with
thickness of 0.1" or more) or "section of building effec-
tively finished with incombustible material."
Note, however, that combustion failure may occur to the
unit as exhaust gas reflects from the wall. Provide clear-
ance of 24" or more in the front of the unit to facilitate
inspection and repair.

24" (12")

or more

0.4" or more

combustible

36" or more

6" or more

6" or more

Surrounding the area of installation

24" or more

47" or more

Required Clearances From Heater

combustible

combustible

combustible

combustible

[ For N-0631S-OD ]

Illustration

 SAR8584C̲001̲014̲E̲J.p65

06.11.15, 1:03 AM

Page 7

Adobe PageMaker 6.5J/PPC

Содержание N-0631S

Страница 1: ...d the warranty to the customer along with the Owner s Guide WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or...

Страница 2: ...Cord 10ft 1 2 Optional Accessories The accessories listed below are not included with the units but may be necessary for installation Outdoor Vent Cap Q ty Shape Part Part Shape Q ty 1 1 Remote Contr...

Страница 3: ...s hard acidic or otherwise impure treat the water with approved methods in order to ensure full warranty coverage WARNING CAUTION Check the Gas Check that the rating plate indicates the correct type o...

Страница 4: ...places where dust or debris will accumulate Dust may block the air supply opening causing the performance of the device fan to drop and incomplete combustion to occur as a result Avoid installation i...

Страница 5: ...t vent as specified For outdoor installation use the outdoor vent cap If it is necessary to vent above the roof line in an outdoor instal lation also use the base of the vent cap for rain protection A...

Страница 6: ...6 Outdoor If possible leave 8 or more on either side of the unit to facilitate inspection If possible leave 24 or more in front of the unit to facilitate maintenance and service if necessary Securing...

Страница 7: ...4 Maintain the following clearance from both combustible and non combustible materials indicates the distance when installing a heat insulat ing board incombustible material other than metal with thic...

Страница 8: ...k or paved driveway located on public property Under veranda porch deck or balcony 7 M indicates clearances required in Canada Maintain clearances in accordance with local installation codes and the r...

Страница 9: ...any building 3 above any forced air inlet within 10 Vent Clearances When Heater is In stalled Outdoors With a Vent Cap All clearance requirements are in accordance with ANSI Z21 10 3 and the National...

Страница 10: ...tration For Installations in Canada clearances are as follows To windows doors gravity air inlets 36 To forced air inlets 6 3 1 1 1 Outdoor Clearances to Opening into Any Building 1 below 1 horizontal...

Страница 11: ...e transfer of vibration Do not drop or apply unnecessary force to the device when installing Internal parts may be damaged and may become highly dangerous Install the unit on a vertical wall and ensur...

Страница 12: ...system Vent Piping Use only UL listed category III vent materials Follow the vent pipe manufacturer s installation instructions Make the vertical section of the exhaust vent as short as possible Main...

Страница 13: ...anufacturer s instructions Slope the horizontal vent 1 4 for every 12 to wards the drain tee Do not vent straight upwards Always have a horizontal section of venting Install a condensation drain in th...

Страница 14: ...t is installed in a mechanical closet provide a 24 clearance in front of the unit to the door If combustion air will be provided through a duct size the duct to provide 60 cubic feet of fresh air per...

Страница 15: ...gas line consult local codes or the National Fuel Gas Code ANSI Z223 1 Natural Gas Meter See next page for the pipe capacity charts Noritz Gas Water Heater 180 000 Btuh Clothes Dryer 35 000 Btuh Barbe...

Страница 16: ...ubic Feet per Hour of Natural Gas 0 60 Specific Gravity 0 5 WC Pressure Drop Length in Feet Pipe Size 3 4 1 1 1 4 1 1 2 2 10 20 30 40 50 60 70 80 90 100 150 200 206 383 614 1261 2934 147 269 418 888 2...

Страница 17: ...dirt before connecting it Take appropriate heat insulation measures e g wrapping with heat insulation materials using electric heaters according to the climate of the region to prevent the pipe from f...

Страница 18: ...hall be provided to temper the water for the other uses to help prevent scalding For Space Heating Purposes Check Valve Aquastat Aquastat Pump Expansion Tank Install According to Local Codes Optional...

Страница 19: ...r supply when not in use When the power is off the freeze prevention in the water heater will not activate resulting in possible freezing damage Do not let the power cord contact the gas piping Tie th...

Страница 20: ...utton on the remote controller To keep the water heater off let the unit sit for 30 sec to return to the original display When setting the maximum temperature to 125 160 F 1 Turn the water heater off...

Страница 21: ...Part RC CORD26 or use 18AWG wire Install according to the National Electrical Code and all applicable local codes Connecting Remote Controller Cord to Unit Keep the remote controller cord away from th...

Страница 22: ...needs to be cleaned it must be performed by a qualified service technician Do not obstruct the flow of combustion and ventilation air The pressure relief valve must be operated once a year to ensure...

Страница 23: ...ns stop and follow the instructions on page 3 of Owner s Guide 6 Turn the gas control manual valve counterclockwise to the on position 7 Turn on electric power to the unit 8 The unit will now operate...

Страница 24: ...LD WATER INLET 3 4 GAS INLET 3 4 HOT WATER OUTLET 3 4 UPPER WALL MOUNT BRACKETS LOWER WALL MOUNT BRACKETS BOTTOM OF CASE BOTTOM OF CASE WIRING THROUGHWAYS 7 1 4 3 1 6 GAS INLET 3 4 1 8 1 8 10 5 6 2 HO...

Страница 25: ...otes on the Installation Location The remote should be installed in an easily accessible location Avoid installing in a place where water or steam can come into contact with the controller Avoid locat...

Страница 26: ...ord Phillips Roundhead Wood Screw Wall Anchor 3 Remove the cover of the remote control mark the location of the screw holes and drill holes for the wall anchors 4 Insert the wall anchors screw the rem...

Страница 27: ...he wall pipe containing the remote controller wires through the hole 4 Slide the junction box packing and the junction box over the remote controller wires and wall pipe protruding from the outside wa...

Отзывы: