3
2.Included Accessories
Part
Shape
Q'ty
Bag
"Step-1"
Flex Feeder
1
Base Junction Support
・
Clamp x3
1
Base Junction
Adapter Set
1
Bag
"Step-2"
Top Flex support
1
Universal Rain Cap
1
Bag
"Step-3"
Rigid 45 Elbow SET
1
Flex 2" Vent Gasket
1
Fastening Screws
2
Aluminum tape
1
Part
Shape
Q'ty
Installation Manual
(This document)
1
EZTR 25 Feet
Start Up Guide
1
Flex Pipe 2"
approximately 25 feet
1
Flex Sleeve
1
The following accessories are included.
Check for any missing items before starting installation.
2
1.General Information
Property damage, personal injury or death can result if these instructions are not followed. They are a guide for
professional installers generally familiar with the installation and maintenance of heating equipment and related vent
systems.
・
Flex Vent 2" Kit is designed only for the installation inside of B-Vent as sleeve.
Do not use it for other installation method. Also do not use it outdoor.
・
Do not use for anything other than designated Tankless Water Heater (including the model manufactured by
others).
・
Flex Vent 2" Kit can be installed at zero clearance to combustible materials.
・
Appliances can be started up immediately after Flex Vent 2" Kit is installed and inspected.
・
Flex Vent 2" Kit vent systems expand and contract slightly during heating cycles and
must be installed following included instructions.
・
Keep Flex vent greater than 40
̊
F(5
℃
) during installation.
Damage will occur if handled or installed at lower temperatures.
・
Information regarding certification of "Flexible vent pipe and connections".
Standard(s)
ULC-S636-08 Standards for type BH Gas Venting Systems
Product
25Feet-Flex Pipe 2"-LE , Flex Vent 2" Rigid 45 Elbow Set - LE
Brand name Living Engineering Co., Ltd.
40°F